NonEX OI-6000 Cube Series Non-EX Wired Gas Sensor Assembly With Display
|
|
Non-Explosion
Proof Model
Cube Series
Wire-Powered
Sensor
Assembly
Optional Radio & Relays
The
OI-6000 Cube Series, a non-explosion proof ambient air single-point
remote gas sensor assembly with wired power (3-wire), 12-25 VDC
voltage, sensor assembly. Uses electro-chemical, PID, or Infrared
sensor elements to detect a variety of gases including O2, H2S,
CO, LEL, CO2, Cl2, SO2, NH3, NO2, PH3 and other toxic gases.
The
OI-6000 comes standard with a graphical LCD screen, three-button
interface, non-intrusive magnetic switches. Designed to reject EMI
and other forms of interference in order to avoid false gas readings.
Non-explosion proof
enclosure
Quickly setup and install a remote sensor
Non-intrusive calibration with MENU, ADD and SUB
Two
front panel LED indicators (Amber & Red)
Digital RS-485
Modbus output
Choice
of sensor elements available for gas detection
Strobe
alarms & horns can be managed by the controller
Rapid response and clearing time
|
OI-6000
Cube Series Non-Explosion
Proof Wired Sensor Assembly
Optional Radio and/or Relays
Technical Specifications
|
| Enclosure
|
Non-Explosion
Proof
| Aluminum Device Enclosure with Plastic Lid |
| Size
& Weight |
7.6" L x 5.1" W x 5.4" H (15.76" L Maximum w/ Antenna)
5 Lbs
|
| Display |
102x64
Resolution Graphical LCD Screen
Transflective (Sunlight Readable) with white LED Backlight |
| Interface |
Three
push buttons: MENU, ADD, SUB
3 Magnetic Non-Intrusive Switches for Calibration (MENU, ADD
and SUB) |
Customizable
Settings
Optional Relays |
2
Individually-Configurable Alarm LED Set-Points
Optional 2 Dry-Contact Relays with Replaceable 4 Amp Fuses |
| Sensor
Options |
Electrochemical,
Infrared, Photo Ionization Detector (PID):
H2S, CO, O2, H2S2K, HCL, HCN, NH3, NH3300, NH3A, NO2, SO2, CO2,
LEL, CL2, PH3, VOC10, VOC20, VOC50, VOC1K, VOC2K, CH2O |
| Power
Voltage | Draw |
Wired
Power (3-Wire) 12 to 35 VDC | 2 Watts Maximum |
| Signal
Output |
Analog:
4-20mA (3-wire)
Digital: RS-485 Modbus digital output |
| Optional
WireFree Radio |
GEN
II 900 MHz Radio or
GEN II 2.4 GHz Radio (for overseas use) |
| Protection |
Power
Electromagnetic Interference (EMI) Filter
4-20 mA Surge Suppression
RS-485 Surge Suppression
|
| Customizable
Settings |
Individually-Configurable Alarm LED Set-Points |
| Tamb
- Temperature Range |
-20C
to +54C / -40F to 130F |
| Humidity
Range |
0%
to 98% Relative Humidity, Noncondensing |
| Warranty |
Hardware:
One year (limited)
Sensor: varies with sensor type |
| Part
Number Formula |
OI-6000-[Sensor
Type]-[Gas]-[Radio Option]-[Relay /Light Option]-C |
|
|

WARNING!
Otis Instruments equipment should only be used in conjunction with
the manufacturer's instructions.
Failure
to follow such instructions could result in serious injury or fatalities.
|
Return
to Brandt Instruments
For
more information Email
Brandt
Instruments, Inc.
18568 Oak Grove Parkway
Prairieville, LA 70769
1-800-337-6291
Phone: 225-673-6776
Fax: 225-673-6725
Copyright © 2002-2026 Brandt Instruments,
Inc.
|
|
|
|