DP-CALC Micromanometers

 
 
TSI DP-CALC Micromanometers, models 5815-5825

DP-CALC Micromanometers
Models 5815 and 5825
(Replace Models 8702/8705)


 
The TSI DP-Calc 5815 and 5825 micromanometers allow you to easily make HVAC pressure measurements. TheDP-Calc instruments can be used with Pitot probes to measure duct velocity. The DP-Calc 5815 is a simple to operate, hand held digital Micromanometer for fast, accurate differential and static pressure measurements. The high performance DP-CALC™ 5825 can calculate flow and has data logging capabilities.

Features and Benefits
  • Measure differential and static pressure from -15 to +15 in. H2O (-3735 to +3735 Pa)
  • Calculate and display velocity when using a Pitot tube
  • Variable time constant
  • Statistics

Applications
  • HVAC commissioning and troubleshooting
  • Testing and balancing
  • Pitot tube duct traverses
  • Static pressure measurements
  • Pressure drop across filters, coils, fans, and diffusers
  • Environmental air flow testing

5825 DP-Calc digital differentail pressure monitor

Model Comparison DP-Calc 5815 vs 5825

5815

5825

Differential and static pressure x x
Velocity with pitot tube x
Sample statistics x
Volumetric flow rate x
Actual and standard velocity x
Variable time constant x
LogDat2 downloading software x
K factor x
Certificate of Calibration x x

Specifications: DP-CALC Models 5815 and 5825

Static/Differential Pressure
 Range1 -15 to +15 in. H2O ( -28.0 to +28.0 mm Hg, -3735 to +3735 Pa)
 Accuracy ±1% of reading ±0.005 in. H2O
(±0.01 mm Hg, ±1 Pa)
 Resolution 0.001 in. H2O (0.1 Pa, 0.01 mm Hg)
Velocity (Pitot Tube)
Range2 250 to 15,500 ft/min (1.27 to 78.7 m/s)
Accuracy3 ±1.5% at 2,000 ft/min (10.16 m/s)
Resolution 1 ft/min (0.1 m/s)
Duct Size (5825) 1 to 250 inches in increments of 0.1 in. (1 to 635 cm in increments of 0.1 cm)
Volumetric Flow Rate (5825)
Range Actual range is a function of velocity, pressure, duct size, and K factor
Instrument Temperature Range
Operating 40 to 113°F (5 to 45°C)
Storage -4 to 140°F (-20 to 60°C)
Data Storage Capabilities (5825)
Range 12,700+ samples and 100 test IDs
Logging Interval (5825) 1 second to 1 hour
Time Constant (5825) User selectable
External Meter Dimensions 3.3 in. x 7.0 in. x 1.8 in. (8.4 cm x 17.8 cm x 4.4 cm)
Meter Weight with Batteries 0.6 lbs. (0.27 kg)
Power Requirements Four AA-size batteries (5815)
Four AA-size batteries or optional AC adapter (5825)
1 Overpressure range = 190 in. H2O (7 psi, 360 mmHg, 48 kPa).
2 Pressure velocity measurements are not recommended below 1,000 ft/min (5 m/s).
3 Accuracy is a function of converting pressure to velocity. Conversion accuracy improves when actual pressure values increase.

Specifications are subject to change without notice


 
 
 

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards

Copyright © 2002-2014 Brandt Instruments, Inc.

Notice: This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures. Brandt Instruments, Inc. reserves the right to make any changes to information, features, and specifications of any product without notice. Brandt Instruments, Inc. has made every effort to ensure the accuracy of information displayed on this web site, however, Brandt Instruments, Inc. is not responsible for typographical errors appearing on this web site. Price and availability information is subject to change without notice.