Representing
Sperian
Instruments
Biosystems Gas Detectors
Biosystems
Index
.. Single
Gas Portables..
.. Multi-Gas
Portables
.. ..MultiPro
... .MultiVision
... .PhD6
... .Cannonball3
.. Fixed
Point Systems
.. Air
Purification
Panel
. .Respirator
Test Bench
. .Cal
Gas & Accessories
. .Application
Notes
|
GasChek
1 Single Channel Fixed Gas Detection System
NOTE: The Biosystems GasChek1 Was Discontinued 3-13-2007
Factory support servicing and parts will continue until 3-13-2014
The
GasChek 1 is a microprocessor based fixed gas detection system designed
to accept the input from a single remotely located oxygen, combustible
or toxic detector assembly.
GasChek 1 systems are designed to provide continuous round-the-clock
monitoring for a variety of common atmospheric hazards including
oxygen deficiency and/or enrichment, combustible gases and
vapors, and specific toxic contaminants such as carbon monoxide
(CO), hydrogen sulfide (H2S), sulfur dioxide
(SO2), chlorine (Cl2), and nitrogen
dioxide (NO2). Remote detector assemblies are
available in explosion proof or non-explosion proof versions.
Both types of detector housing include digital readouts
and switches which allow for single person, non-intrusive
calibration adjustment.
All GasChek 1 systems include
built in digital readouts at both the controller and remote detector.
Other standard features include two independently adjustable alarm setpoints,
built in audible alarm, bright LED alarm light indicators and relay contacts
for fault, low and high alarm conditions; 1-5 Volt or 4-20 mA user configurable
analog output, and built-in 12V sealed lead acid battery backup power supply. |
|
Features
-
Round-the-clock monitoring for
a wide variety of atmospheric hazards
-
Easy to install and operate
-
Weatherproof NEMA 4X controller
housing
-
Digital readouts at both controller
and
remote detector
-
Two independently adjustable
alarm levels
-
Comprehensive output relays
for remote signaling and control
-
Single person, non-intrusive
calibration adjustment
-
Built-in backup power supply
|
Technical Specifications:
| Gas Channel
Inputs |
All remote detector
assemblies: 4-20 mA current loops |
| GasChek 1 Outputs |
Fault, low and
high alarm, DPDT relay - contacts rated 5 Amp at 250 VAC, non-inductive
load; and 1-5 Volt or 4-20 mA user configurable analog output. |
| GasChek 1 Displays |
Controller:
Red LED - 3 digit 7 segment for gas level (flashes for over-range); Remote
detector: 3 1/2 digit LCD |
| GasChek 1 Indicators
(LED) |
Green: main
power, battery, measurement units (ppm, % LEL, % volume); red: low alarm,
high alarm; amber: fault |
| Power Requirements |
110/220/240 VAC - 50/60
Hz, 12/24 VDC, 50 W max. |
| Temperature Range |
14 to 104 degrees Fahrenheit
(-1O to +40 degrees Celsius) |
| Humidity Range |
0 to 95% RH, noncondensing |
| Weather Protection |
NEMA 4X |
| Dimensions |
GasChek 1 controller: 11.2"
(28cm) x 9.2" (23cm) x 6.2" (15.5cm) |
| Weight |
GasChek 1: 9 lbs (4kg) |
WARNING!
Sperian equipment should only be used in conjunction with the
manufacturer's instructions.
Failure
to follow such instructions could result in serious injury or
fatality.
|
|
Return
to Brandt Instruments
For
more information Email
Brandt
Instruments, Inc.
18568 Oak Grove Parkway
Prairieville, LA 70769
1-800-337-6291
Phone: 225-673-6776
Fax: 225-673-6725
Copyright © 2002-2010 Brandt Instruments,