Representing Sperian Instruments Biosystems Gas Detectors
Biosystems
Index
|
Biosystems
Cannonball3
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cannonball3 Features
DESIGN
Rugged RFI-protected case designed for the most demanding environments IP65 rated protection against dust and water One button operation Oversized (5" diagonal) backlit graphic display with automatic backlight Super bright alarm lights visible in any direction Multiple languages SMART SENSORS AND CALIBRATION
Four sensors. O2, LEL and up to three toxic channels using Biosystems' Duo-Tox two channel CO/H2S sensor (see matrix for available sensors) Field replaceable sensors One button auto calibration Calibration due reminder Sensor span reserve indicators during calibration for predictive maintenance High sensitivity PPM hydrocarbon sensor configuration
RECORDING
Black Box recorder with over 100 hours of storage Available with optional datalogging for convenient and easy downloading to a computer PUMPS Filed replaceable pump module Available with dual pumps for accurate dilution monitoring in inert environments without the use a dilution orifice Dilution calibration regardless of tube length Automatic low flow alarm Automatic leak test before every use BATTERIES
Interchangeable Alkaline (5 "D"-cell) and rechargeable (NiMH) batteries Operating life Alkaline: Up to 24 hours NiMH: Up to 16 hours Snap-on fast charger included with rechargeable (NiMH) configuration Recharges in 4 hours
| Size: | 12" x 6" x 6". |
| Weight: |
Alkaline
battery version 6.7 lbs. NiMH battery version 6.5 lbs. |
| Intrinsic Safety |
UL Class I Division 1 Groups A,B,C,D Temp
T3C. CSA Class I Division 1 Groups A,B,C,D Exia Temp T3C. |
| Durability | Meets IPX5 water standard. |
| Display | Oversized LCD display. |
| Audible Alarm | Two-toned alarm rated at 105 dB @ 30 cm. |
| Visual Alarm | Three bright red multidirectional LED alarms. |
| Display Backlight | Automatically-activated. |
| Controls | One-button automatic calibration. |
| Housing | Chrome metal-plated ABS. Internal RFI shielding provides RFI immunity to 40 V/m. |
| Battery Options | Alkaline or rechargeable NiMH (Nickel Metal Hydride) battery packs. |
| Run Time | 16 hrs NiMH, 20 hrs Alkaline. |
|
Cannonball3 |
Standard
Version (1pump) |
Dilution
Version (2 Pumps) |
||
|---|---|---|---|---|
|
Alkaline |
NiMH |
Alkaline |
NiMH |
|
| No Sensors
Installed |
54-34-00000-A |
54-34-00000-N |
54-35-00000-A
|
54-35-00000-N |
| LEL / O |
54-34-30000-A |
54-34-30000-N |
54-35-30000-A |
54-35-30000-N |
| LEL / O /
CO |
54-34-30100-A |
54-34-30100-N |
54-35-30100-A |
54-35-30100-N |
| LEL / O /
CO-H |
54-34-31900-A |
54-34-31900-N |
54-35-31900-A |
54-35-31900-N |
| LEL / O /
H2S |
54-34-30200-A |
54-34-30200-N |
54-35-30200-A |
54-35-30200-N |
| LEL / O /
Duo-Tox (CO/H2S) |
54-34-31400-A |
54-34-31400-N |
54-35-31400-A |
54-35-31400-N |
| LEL / O /
CO / H2S |
54-34-30102-A | 54-34-30102-N | 54-35-30102-A | 54-35-30102-N |
| LEL / O /
SO2 |
54-34-30300-A |
54-34-30300-N |
54-35-30300-A |
54-35-30300-N |
| LEL / O /
CO / SO2 |
54-34-30103-A |
54-34-30103-N |
54-35-30103-A |
54-35-30103-N |
| LEL / O /
H ,S / SO,' |
54-34-30203-A |
54-34-30203-N |
54-35-30203-A |
54-35-30203-N |
| LEL / O /
Duo-Tox (CO/H2S)/SO2 |
54-34-31403-A |
54-34-31403-N |
54-35-31403-A |
54-35-31403-N |
| LEL / O / SO2 Ext. |
54-34-31500-A |
54-34-31500-N |
54-35-31500-A |
54-35-31500-N |
| LEL / O / NH3 |
54-34-32100-A |
54-34-32100-N |
54-35-32100-A |
54-35-32100-N |
| LEL / O / CI2 (non-specific) |
54-34-30800-A |
54-34-30800-N |
54-35-30800-A |
54-35-30800-N |
| LEL / O / CI2 (specific) |
54-34-31800-A |
54-34-31800-N |
54-35-31800-A |
54-35-31800-N |
| LEL / O / CIO2 (non-specific) |
54-34-31200-A |
54-34-31200-N |
54-35-31200-A |
54-35-31200-N |
| LEL / O / CIO2 (specific) |
54-34-32000-A |
54-34-32000-N |
54-35-32000-A |
54-35-32000-N |
| LEL / O, / NO2 |
54-34-30900-A |
54-34-30900-N |
54-35-30900-A |
54-35-30900-N |
|
The dilution
version of the Cannonball3 allows for accurate gas
detection in inert environments without the use of a dilution
orifice. |
||||
|
The detection
range of the standard SO2 sensor is 0.0 - 25 in 0.1
PPM increments. |
||||
| Option |
Code
|
Comments
|
|
Alkaline |
A |
NiMH battery pack and charger
may be purchased separately. |
|
Rechargeable |
N |
NiMH configuration includes
charger. Alkaline battery packs may be purchased |
|
Datalogging |
D |
Enables the Cannonball3 to
record and download measurements. This option is available as
an upgrade after purchase. Download software must be purchased
separately. Computer must support IrDA to download. |
|
TouchID™ |
T |
This option includes both
datalogging and TouchID™ reader. TouchID™ buttons
and programming software must be purchased separately. |
|
Remote Alarm |
R |
Remote alarm connector is
required to connect an optional remote alarm device. Remote alarm
device must be purchased separately. |

| Part No. |
Description
|
Range | Resolution | ||
|
54-25-80 |
LEL |
Combustible
Gas |
|
0 -100% LEL |
1 % LEL |
|
54-25-71 |
LEL |
HC-PPM Combustible
Gas |
|
0-9999 PPM |
10 PPM |
|
54-25-90 |
O2 |
Oxygen |
|
0 -30%/Vol |
0.1% |
|
54-25-01 |
CO |
Carbon monoxide |
|
0 -1000 PPM |
1 PPM |
|
54-25-05 |
|
CO Plus dual
purpose CO / H2S |
CO: |
0 -1000 PPM |
1 PPM |
|
54-25-19 |
CO-H |
CO Minus,
reduced sensitivity to H2 |
|
0 -800 PPM |
1 PPM |
|
54-25-02 |
H2S |
Hydrogen sulfide |
|
0 -200 PPM |
1 PPM |
|
54-25-14 |
Duo-Tox |
Dual channel
CO/ H2S |
CO: H2S: |
0-1000 PPM |
1 PPM |
|
54-25-03 |
SO2 |
Sulfur dioxide |
|
0-25 PPM |
0.1 PPM |
|
54-25-15 |
SO2-Ext |
Sulfur dioxide
extended range |
|
0-100 PPM |
1 PPM |
|
54-25-211 |
NH3* |
Ammonia |
|
0-300 PPM |
1 PPM |
|
54-25-081 |
CI2 |
Chlorine (non-specific) |
|
0-50 PPM |
0.1 PPM |
|
54-25-181 |
CI2 |
Chlorine (specific) |
|
0-50 PPM |
0.1 PPM |
|
54-25-121 |
CIO2 |
Chlorine dioxide
(non-specific) |
|
0-15 PPM |
0.1 PPM |
|
54-25-201 |
CIO2 |
Chlorine dioxide
(specific) |
|
0-5 PPM |
0.01 PPM |
|
54-25-091 |
NO2 |
Nitrogen dioxide |
|
0-50 PPM |
0.1 PPM |
|
54-25-13 |
PH3 |
Phosphine |
|
0-20 PPM |
0.1 PPM |
|
|
|||||
|
Note:
The non-specific
CI, and CIO, sensors can be used for the detection of both gases.
The specific CI, and CIO, sensors are designed for the target gas only. |
|||||
|
Part No.
|
Description
|
|
35-0379 |
Cannonball3
motorized sample draw pump module |
|
35-0378 |
Cannonball3
motorized sample draw pump module for dual pump version (2 pumps). |
|
54-36-01 |
Cannonball3
Remote audible and visible alarm. |
|
35-0376 |
Cannonball3
Alkaline batter pack ("D"-Cell batteries not included) |
|
35-0377 |
Cannonball3
NiMH battery pack |
|
54-26-0603 |
Cannonball3
BioTrak Software Kit. Includes BioTrak software and manual' |
|
54-26-0605 |
Infrared
communication device Serial - IrDA - |
|
54-27-0802 |
TouchID™
programming kit. Includes software, programming wand, serial connector,
10 |
|
Part No.
|
Description
|
|
13-174 |
Cannonball3
Reference Manual |
|
13-175 |
Cannonball3
Quick Reference Guide |
|
22-143 |
Cannonball3
Training Video |
|
42-002 |
Cannonball3
Shoulder strap |
|
54-36-20 |
Cannonball3
Gasket service kit. Includes
6 filter gaskets, 2 pump gasket, 2 battery gasket and lubricant
for gaskets |
|
54-36-17 |
Internal filter
kit for Cannonball3. (10 ea. particulate and 5 ea. hydrophobic). |
| Part No. |
Description
|
|
35-0379 |
Cannonball3 motorized
sample draw pump |
|
35-0378 |
Cannonball3
motorized
sample draw pumps for dual pump version. |
|
54-36-03 |
Cannonball3
Sample probe
with plastic extension and male quick disconnect |
|
54-36-04 |
Cannonball3 Sample robe
with stainless steel extension and male quick disconnect |
|
54-36-05 |
Cannonball3
Sample robe
with plastic extension and threaded for quick disconnect fitting. |
|
54-36-06 |
Cannonball3
Sample robe
with stainless steel extension and threaded for quick disconnect
fitting |
|
54-36-07 |
Cannonball3
Sample robe
male quick disconnect |
|
54-36-08-010 |
Cannonball3
Extension
hose, 10 feet with male and female quick disconnect |
|
54-36-08-025 |
Cannonball3 Extension
hose, 25 feet with male and female quick disconnect |
|
54-36-08-050 |
Cannonball3
Extension
hose. 50 feet with male and female quick disconnect |
|
54-36-08-100 |
Cannonball3 Extension
hose, 100 feet with male and female quick disconnect |
|
54-36-09 |
Cannonball3 set of male
and female quick disconnects |
|
54-36-01 |
Cannonball3 Remote audible
and visible alarm |
| Part No. |
Description
|
|
54-36-10 |
Cannonball3
Snap-On fast charger 110VAC |
|
54-36-11 |
Cannonball3
Snap-On fast charger 12VDC (Available 3' Qtr 2001 |
|
35-0376 |
Cannonball3
Alkaline batter pack batteries not included |
|
35-0377 |
Cannonball3
NiMH battery pack |
|
54-36-13 |
Cannonball3
Datalogger upgrade. Download software not included. |
|
54-26-0603 |
Cannonball3
BioTrak Software Kit. Includes BioTrak software and manual |
|
54-26-0605 |
Infrared communication
device Serial - IrDA - |
|
54-27-0802 |
TouchID™ programming
kit. Includes software, programming wand, serial connector, 10
buttons, 10 key chain / wall mounts for TouchID™ buttons and 10 TouchID™ badges |
|
54-27-0805 |
10 TouchID™ buttons |
|
54-27-0811 |
100 TouchID™ buttons |
|
54-27-0807 |
10 TouchID™ key ring /
wall mounts. Does not include TouchID buttons |
|
54-27-0812 |
100 TouchID™ key ring /
wall mounts. Does not include TouchID buttons |
|
54-27-0810 |
10 TouchID™ badges. Does
not include TouchID™ buttons |
|
54-27-0813 |
100 TouchID™ badges. Does
not include TouchID™ buttons |
|
Computer
must be equipped with infrared adapter (IrDA) to download |
|
|
Part N
|
Description
|
|
54-36-14 |
Cannonball3
Calibration kit. Includes foam-lined carrying case with room for
up to three cylinders of calibration gas. Kit contains 12-023
regulator and other fittings. Kit does not include gas. |
|
35-0453 |
Cannonball3
Waterproof "Pelican" style carrying case with room for one Cannonball3
and one cylinder of calibration gas |
|
54-36-15 |
Cannonball3
Calibration tube with male quick disconnect |
|
54-36-18 |
Cannonball3
Calibration balloon ( not for use with Cl2 and CIO2). |
|
54-36-16 |
Cannonball3
Inert calibration tube (for reactive gases) with male quick disconnect |
WARNING!
Sperian equipment should only be used in conjunction with the manufacturer's
instructions.
Failure