Toxi Vision®
Single Gas
Detector
From Sperian Instruments
December
2009
The Biosystems Toxi Vision single gas detector has been discontinued
Servicing,
spare parts & accessories will be available until December
2012
It has been replaced by the ToxiPro
Single Gas Meters
Toxi
Vision IR and Toxi
Vision EX versions will continue to be manufactured
| |
The Biosystems Toxi Vision is a durable, single-sensor
gas detector which features a rugged metal-plated
case that is immune to both RFI and the elements.
One-button operation keeps it simple. A few minutes
of training is all it takes to ensure proper operation.
Available in the standard O2, H2S, CO as well as toxic
sensors such as NH2, SO2, NO2, PH3, Cl and other gases
for hazardous areas.
Also available with an
IR sensor for monitoring CO2 or methane.
The large liquid crystal display can be easily seen
from several feet away. A manually-activated backlight
ensures the visibility of the readings even in low
light conditions.
An audible alarm and bright LED alarm light warn users
of dangerous conditions, while an optional vibrating
alarm is available for use in high-noise environments.
Each set of 2 easily-changed AA alkaline batteries
provides months of continuous operation.
|
 |
|
|
|
 |
Toxi
Vision Key Features
- Choice
of sensors- Toxi Vision detectors are available to monitor
for an increasing variety of common atmospheric hazards.
Choose from substance-specific sensors for the detection
of O2, CO and H2 and a number of toxic
sensors for hazardous environments.
|
- RFI
Protection- Special RFI shielding prevents operating
interference from two-way radios and other electronic devices
providing RFI immunity to 40 V/m.
|
- Display
size- The display is among the largest on the market
for single sensor gas detectors. It can easily be seen from
several feet away.
|
- Durability-
The chrome metal-plated ABS case makes the Toxi Vision
resistant to corrosive gases such as H2S. The
Toxi Vision is also vacuum-tested to ensure water tightness
and has a water-resistance rating of IPX5/7.
|
- One-button
operation- A single button controls access to all user
functions and is large enough to be used even with gloves
on.
|
- Optional
vibrator alarm- An optional internally-housed vibrator
alarm allows the detector to be used even in high noise
environment.
|
- Calibration-
True one-button auto calibration is available at any
time while in normal operation. Simply press the "MODE"
button three times, attach the adapter, and flow gas to
the sensor. All adjustments are automatic.
|
-
Standard
Accessories: Every Toxi Vision detector comes complete
with belt clip, calibration adapter, installed set of
2 AA batteries, reference manual and quick reference card
|
|
|
| Toxi
Vision Specifications |
| Display: |
Oversized
Liquid Crystal Display which can be seen from several feet away |
| Backlight: |
Backlight
activates with button and any alarm |
| Housing: |
Satin
nickel-plated, RFI resistant ABS with immunity to 40 V/m |
| Clip: |
Built-in
steel clip |
| Power: |
2 AA batteries |
| Weight: |
6.7oz. (190g) |
| Battery
life: |
Up to 4,000
continuous hours per set of batteries |
| Dimensions: |
3.5" (8.9 cm)
x 2.5 " (6.4 cm) x 1.25 " (3.25 cm) |
| Alarms: |
Factory-set
alarm levels |
| Audible
Alarms: |
Loud
warbling two-toned alarm rated at 92 dBA @ 1 foot |
| Visual
Alarms: |
Bright
red LED alarm light |
| Security
Flash: |
Security
beep in variable intervals is available. A blinking light always
means Attention Required. A 2x blinking alarm every 5 seconds means
Needs Cal. A continuously blinking means Alarm |
| Optional
Vibrator Alarm: |
For high
noise environments
|
|
Intrinsic
Safety:
(Toxic &
Oxygen)
|
UL Class
I, Division 1, Groups A, B. C, D
CSA Class
I, Division 1, Groups A, B. C, D
ATEX
II 2 Ex d ia IIC T4
ICQST Ex IA IIC T
|
|
Intrinsic
Safety:
(Toxi Vision
EX)
|
UL Class
I, Division 1, Groups A, B. C, D
CSA Class
I, Division 1, Groups A, B. C, D
ATEX
II 2 Ex d IA IIC T4
IECEx Ex d IA IIC T4
NEPSI Ex
d IA IIC T4
|
|
Intrinsic
Safety:
(Toxi Vision
IR)
|
UL Class
I, Division 1, Groups A, B. C, D
ATEX
II 2 Ex d IA IIC T4
IECEx Ex d IA IIC T4
NEPSI Ex
d IA IIC T4
|
| Ingress
Protection: |
Alkaline
version meets IPX7 water standard.
Rechargeable version meets IPX5. |
|
| Toxi
Vision Detector Kit Options |
| Part
Number |
Description |
| 54-37-90 |
O2
Oxygen sensor |
| 54-37-01 |
CO
Carbon monoxide sensor |
| 54-37-05 |
CO+
Carbon monoxide plus sensor |
| 54-37-19 |
CO-H
Carbon monoxide minus sensor
(reduced x-sensitivity to
H2S) |
| 54-37-02 |
H2S
Hydrogen sulfide sensor |
| 54-37-03 |
SO2
Sulfur dioxide sensor |
| 54-37-21+ |
NH3
Ammonia sensor |
| 54-37-08 |
Cl2
Chlorine sensor (non-specific) |
| 54-37-09 |
NO2
Nitrogen dioxide sensor |
| 54-37-18+ |
Chlorine
(Cl2) sensor (specific) |
| 54-39-12+ |
ClO2
Chlorine Dioxide (non-specific) |
| 54-39-20 |
ClO2
Chlorine Dioxide (specific) |
| 54-39-09 |
NO2
Nitrogen Dioxide |
| 54-37-10 |
HCN
Hydrogen cyanide sensor |
| 54-37-13 |
PH3
Phosphine sensor |
+Note: Special reactive gas calibration adapter and tubing
is required for proper calibration.
Special
reactive gas regulator 12-025 is needed
|
|
Toxi Vision detectors may
be ordered separately or as part of a Value Pack kit.
-
Standard
Accessories: Every Toxi Vision detector comes complete with
belt clip, calibration adapter, installed set of 2 AA batteries,
rechargeable NiMH version includes charger, reference manual and
quick reference card.
- Value Pack Kit:
All standard accessories, compact size (34 liter) cylinder of calibration
gas, fixed flow regulator, foam-lined carrying case. Add "K"
to the part number.
- To
order any Toxi Vision detector equipped with the optional internal
vibrating alarm add "V" to the part number.
- Add "B"
to the part number to order with rubber boot.
|
| Toxi
Vision Accessories |
| Part
Number |
Description
|
| 54-38-01 |
Calibration
/ sample draw adapter |
| 54--38-09 |
Calibration
adapter: includes FEP lined tubing for reactive gases - NH3, Cl2,
ClO2, HCN & NO2 |
| 54-38-03 |
Rubber
Boot |
| 54-38-04 |
Toxi
Vision PC Programming Kit. Includes software and serial interface
cable |
| 54-38-05 |
Replacement
Belt Clip |
| 54-38-06 |
Manual
Sample Draw Kit. Includes adapter and 10' of tubing
NOT
FOR USE WITH CORROSIVE GASES: Cl2, ClO2 or
NH3 |
| 54-38-07 |
Case
for Value Pack. Foam-limed ABS with room for (1) 34-liter gas cylinder |
| 35-964 |
Lanyard
for Toxi Vision |
| Toxi
Vision Replacement Sensors |
| Part
Number |
Description
|
| 54-39-01 |
Carbon
monoxide sensor |
| 54-39-02 |
Hydrogen
sulfide sensor |
| 54-39-03 |
Sulfur
dioxide sensor |
| 54-39-05 |
Carbon
monoxide plus (CO+) sensor |
| 54-39-08 |
Chlorine
(Cl2) sensor (non-specific) |
| 54-39-09 |
Nitrogen
dioxide (NO2) sensor |
| 54-39-18 |
Chlorine
(Cl2) sensor (specific) |
| 54-39-19 |
Carbon
monoxide minus (CO-H) sensor (reduced cross-sensitivity to H2S) |
| 54-39-21 |
Ammonia
(NH3)sensor |
| 54-39-90 |
Oxygen
sensor |
| 54-39-10 |
Hydrogen
Cyanide (HCN) sensor |
| 54-39-13 |
Phosphine
(PH3) sensor |
WARNING!
Sperian equipment should only be used in conjunction with the manufacturer's
instructions.
Failure
to follow such instructions could result in serious injury or fatality.
|
Sperian - Biosystems Toxi Vision®
CO Responder Kit
The kit
was discontinued effective 1-01-2009
|
|
The Sperian
- Biosystems CO Responder Kit is the complete and accurate solution for
both residential and workplace carbon monoxide calls. The kit includes a
rugged and dependable ToxiVision CO gas detector, a cylinder of calibration
gas with regulator and all necessary calibration fittings, ten easy-to-use
ToxiTube CO dosimeter tubes, operator's manual and quick reference card
- all in a durable waterproof carrying case.
The Toxi Vision CO Responder Kit
was built with the fire service in mind. The kit includes everything you
need to calibrate and operate the ToxiVision and 10 ToxiTube dosimeter
tubes that can be left behind to continue monitoring for CO for an additional
24 hours.
|
ToxiTube dosimeter tubes are designed
to respond to background carbon monoxide and give an indication of the approximate
level of gas. Just break the tube on the score line and leave it in the
area to be monitored. Positive CO readings show up as a stain on the internal
filament and warn the resident of potential CO hazards.
Ordering Information
- The kit
was discontinued effective 1-01-2009
| Item |
Part Number |
| ToxiVision
CO Responder Kit |
54-37-01RK |
| ToxiVision
CO Gas Detector |
54-37-01 |
| Replacement
10-Pack ToxiTubes |
54-38-11 |
| Replacement
34-liter cylinder CO Cal Gas |
54-9036 |
|
|
|
|
Return
to Brandt Instruments
For
more information Email
Brandt
Instruments, Inc.
18568 Oak Grove Parkway
Prairieville, LA 70769
1-800-337-6291
Phone: 225-673-6776
Fax: 225-673-6725
Copyright © 2002-2010 Brandt Instruments,