Representing
Sperian
Instruments now
Honeywell Analytics
Biosystems Gas Detectors
Biosystems
Index .. Single
Gas Portables..
.. Multi-Gas
Portables
.. ..MultiPro
... .MultiVision
... .PhD6
... .Cannonball3
.. Fixed
Point Systems
.. Air
Purification
Panel
. .Respirator
Test Bench
. .Cal
Gas & Accessories
. .Application
Notes |
Biosystems FXC 4-Channel
Controller
For
One to Four Channel
Fixed Gas Detection Systems
Biosystems EXP, NXP & 4-20 mA Systems
From Sperian Instruments now Honeywell Analytics
Effective
May 31, 2011, the Biosystems NXP and Biosystems EXP Fixed Gas Detection
Systems,
as well as the Biosystems FXC Fixed System Controller, have been discontinued.
Standard warranties for product related concerns will continue to be
honored.
Servicing, spare parts, and accessories will be available until May
31, 2013, or until parts are no longer available.
|

Biosystems
FXC 4-Channel Controller
|
The Sperian
Instruments Biosystems FXC Fixed System Controller is a
1-4 channel gas detection controller for fixed systems allowing
remote gas detection of O2, LEL combustible or toxic gas
sensors.
The FXC is compatible
with the Biosystems NXP, EXP single channel fixed systems
or any 4-20 mA transmitters.
|
FXC
Controller 4-Channel Key Features
|
|
|
FXC
Controller Technical Specifications
|
| Housing |
Rugged,
durable for use in harsh environments |
| Dimensions |
11.5" x 10.0" x 7.0" (29 cm x 25 cm x 18 cm) |
| Power
Requirements |
15-24
VDC, 115 VAC |
| Display |
Large
easy to read 4-digit LCD for gas reading |
| Display
LEDs |
Channel,
DC and AUX alarms |
| Relay
Outputs |
15-24
VDC (Low and High alarms)
Dry Contact (AUX Low and AUX High alarms) |
| Temperature
Range |
System components
designed to function over range of
0° to 167° F (-17.5° to 75° C)
Type of sensor installed may modify range. |
| Audible Alarm |
Rated at 97dB at
3 ft / 1 m |
| Visual Alarm |
Optional Visual Alarm:,
Amber and/or Red strobes |
| Weight
|
7 Lbs |
|
FXC
Controller Ordering Information
|
| Part
# |
Description |
| FXC
- Standard Audible Horn |
54-63-C00
|
Controller
with no strobes |
54-63-C10
|
Controller
with an Amber Strobe |
54-63-C20
|
Controller
with a Red Strobe |
54-63-C30
|
Controller
with an Amber and Red Strobe |
| FXC
— With High Intensity Audible Horn |
54-63-C01
|
Contoller
with no strobes |
54-63-C11
|
Controller
with an Amber Strobe |
54-63-C21
|
Controller
with a Red Strobe |
54-63-C31
|
Controller
with an Amber and Red Strobe |
|
|
|
WARNING!
Honeywell Analytics - Biosystems equipment should only be used
in conjunction with the manufacturer's instructions. Failure
to follow such instructions could result in serious injury or
fatality.
|
|
Return
to Brandt Instruments
For
more information Email
Brandt
Instruments, Inc.
18568 Oak Grove Parkway
Prairieville, LA 70769
1-800-337-6291
Phone: 225-673-6776
Fax: 225-673-6725
Copyright © 2002-2012 Brandt Instruments,
Inc.
Notice:
This publication is intended for general information only and
should not be used as a substitute for reviewing applicable
government regulations, equipment operating instructions, or
legal standards. The information contained in this document
should not be construed as legal advice or opinion nor as a
final authority on legal or regulatory procedures. Brandt Instruments,
Inc. reserves the right to make any changes to information,
features, and specifications of any product without notice.
Brandt Instruments, Inc. has made every effort to ensure the
accuracy of information displayed on this web site, however,
Brandt Instruments, Inc. is not responsible for typographical
errors appearing on this web site. Price and availability information
is subject to change without notice.
|
|
|