Sperian Instruments now Honeywell Analytics, Biosystems MultiVision gas detectors,multi gas meters, confined space meter, rated IPX7,
Representing
Sperian Instruments
now Honeywell Analytics
Biosystems Gas Detectors

 

Biosystems Index
.. Single Gas Portables..
.. Multi-Gas Portables

..   ..MultiPro
...   .MultiVision
...   .PhD6
...   .Cannonball3
.. Fixed Point Systems
.. Air Purification Panel
. .Respirator Test Bench
. .Cal Gas & Accessories
. .Application Notes

 
 

Biosystems, Sperian Instruments, Honeywell, gas detectors, MultiPro, PhD6, ToxiPro, ToxiLTD, IQ Docking Stations, PosiChek3 SCBA Testing, calibration gas


Honeywell Biosystems
MultiVision™ Multi-Gas Monitor
Gas Detection from Sperian Instruments
Now Honeywell Analytics


home biosystems index Biosystems MultiVision Gas Detector

The Biosystems MultiVison was officially discontinued on July 30, 2011.
Standard warranties for product related concerns will continue to be honored. Only sensors are now available.


Replaced by the Honeywell IQ Force Meters

Biosystems MultiVision Confined Space Gas Detector The Biosystems MultiVision - toxic & combustible monitors for hazardous locations. The multi-gas detectors can use up to four independent sensors for oxygen, combustible gas, carbon monoxide, and hydrogen sulfide.

The MultiVision has run times of up to 20 hours in diffusion mode and up to 16 hours  when using the internal the pump  and NiMH battery pack. Alkaline battery packs yield run times of up to 16 hours in diffusion mode and up to 12 hours with the  internal pump on between battery changes. 

The instrument case is made of chrome-plated ABS and is rated to IPX5 / IPX7 against water ingress (immersible) and is rated for RFI immunity to 40 V/m. 

A single button located on the left side of the instrument controls all day-to-day instrument functions including:
  • turning on the backlight
  • scrolling through the current gas readings, MAX and TWA screens
  • initiating calibration sequences
MultiVision 4-Gas Meter Being Used
MultiVision Navigation Button to  Kit Options MultiVision Navigation Button to  Specifications MultiVision Navigation Button to Sensors MultiVision Navigation Button to  Accessories MultiVision Navigation Button to  Sampling Accessories MultiVision Navigation Button to IQ Dock MultiVision Navigation Button to Calibration Gases MultiVision Navigation Button to  Caibration Kits & Cases


MultiVision Features

  • Compact design The MultiVision's sleek, tapered design easily fits in your hand, or uses its belt clip for hands-free monitoring . 
  • Optional built-in motorized sample pump The MultiVision may be equipped with a built-in motorized sample draw pump. The pump version features automatic switching between pump and diffusion modes. 
  • Rugged and weatherproof The MultiVision's durable and impact-resistant chrome-plated ABS case is rated to IPX5 / IPX7 against water ingress (immersible). 
  • Serious RFI protection The MultiVision is immune to Radio Frequency Interference to 40 volts per meter. 
  • One button operation The MODE button on the left side of the instrument controls all day-to-day functions including initiation of the automatic calibration sequence. 
  • Battery options The MultiVision comes equipped with your choice of interchangeable Alkaline or NiMH battery packs. NiMH versions also include a drop-in charger. 
  • Hazardous certification UL classified for Class 1, Division 1 Groups A,B,C,D Hazardous Locations. Other certifications pending. 
  • Long battery life The rechargeable NiMH battery runs the MultiVision for up to 20 hours in diffusion mode or up to 16 hours with the pump on between charges. Alkaline battery packs yield run times of up to 16 hours in diffusion mode or up to 12 hours with the pump on. 
  • Loud audible alarm The audible alarm is rated to 92 dBA at 1 foot. 
  • Built-in black box data recorder Every MultiVision includes a built-in "black box" data recorder that can store more than 30 hours of instrument readings and other data. 
  • Optional Datalogger The "black box" Datalogger can be updated to a full datalogging instrument at any time. 

MultiVision Specifications

Size: 6" x 3.4" x 2.5" (15 x 8.6 x 6.4 cm)
Weight: 20 oz. (570 g)
Intrinsic Safety: UL Classified for Class 1 Division 1 Groups A,B,C,D Hazardous Locations.
Other certifications pending
Durability: Meets IPX5/IPX7 water standard
Display: Oversized 2" x 1.5" LCD display.
Audible Alarm: Loud warbling, two-tone alarm rated at 92 dBA at one foot. 
Visual Alarm: Bright red LED alarm.
Display Backlight: Activates with MODE button.
Controls: One-button automatic calibration.
Housing: Chrome metal-plated, RFI resistant ABS with RFI immunity to 40 V/m. 
Battery Options: Alkaline or rechargeable NiMH (Nickel Metal Hydride) battery packs. 
Battery Life (diffusion): 20 hours NiMH, 16 hours Alkaline. 
Battery Life with Pump: 16 hours NiMH, 12 hours Alkaline. 


Kit Options

Standard Accessories: Each MultiVision detector is shipped complete with standard accessories including belt clip, calibration adapter and tubing, reference manual, quick reference card, and training CD-ROM.

  • Alkaline MultiVision detectors come with an alkaline battery pack and a set of three AA disposable batteries.
  • Rechargeable MultiVision detectors include a Nickel Metal Hydride (NiMH) battery pack and slip-in charger cradle.
  • MultiVision detectors are also available as Confined Space Kits and Value Pack Kits.
  • Confined Space Kits include all standard accessories plus an all-in-one large cylinder of calibration gas (58 or 103 liters), fixed flow regulator and calibration adapter all in a waterproof "pelican-style" carrying case.
  • Value Pack Kits include an alkaline MultiVision detector with standard accessories plus large all-in-one small cylinder of calibration gas (34 liters), fixed flow regulator and calibration adapter all in a hard-shell carrying case.
    .
  • DESCRIPTION
    MultiVision Confined Space Gas Detector
    Part Number
    Alkaline
    MultiVision
    Rechargeable
    MultiVision
    NiMH 
    MultiVision
    Value Pack
    MultiVision
    Alkaline CSK
    MultiVision
    NiMH CSK
    MultiVision with LEL / O2 sensors  54-40-30000A 54-40-30000N 54-40-30000AV 54-40-30000AC 54-40-30000NC
    MultiVision with LEL / O 2 / CO sensors  54-40-30100A 54-40-30100N 54-40-30100AV 54-40-30100AC 54-40-30100NC
    MultiVision with LEL / O2 / H2S sensors  54-40-30200A 54-40-30200N 54-40-30200AV 54-40-30200AC 54-40-30200NC
    MultiVision with LEL / O2 / CO / H2S sensors  54-40-30102A 54-40-30102N 54-40-30102AV 54-40-30102AC 54-40-30102NC

    Options
    Pump Allows the user to switch automatically between sample draw and diffusion mode by attaching and detaching the sample draw adapter.
    Datalogging Enables the MultiVision to record and download measurements. Necessary to order to be IQ-Dock compatible. Download software must be purchased separately. Computer must support infrared communication (IrDA) to download.
    54-41-008 MultiVision BioTrak Download Software
    54-26-0605 Infrared communication device. Specify serial (S) or USB (U) Requires one available PC serial or USB port.

     

    Biosystems MultiVision Confined Space Kit
    Biosystems MultiVision Meters with Protective Boots
    MultiVision Confined Space Kit
    MultiVision Meters with Protective Boots

     

    Most Common MultiVision Accessories

    Part No. Description
    54-41-004B
    MultiVision Rubber Boot. Black
    54-41-004R
    MultiVision Rubber Boot. Red
    54-41-004Y
    MultiVision Rubber Boot. Yellow
    54-41-007
    MultiVision Manual Sample draw kit. Includes adapter, squeeze bulb, 10' of tubing.
    54-41-008
    MultiVision BioTrak Download software. Requires MultiVision datalogging option be installed. Computer must support infrared communication IrDA to download.
    54-26-0605S
    Infrared communication device Serial - IrDA - Requires one available PC serial port.
    54-26-0605U
     I Infrared communication device (USB - IrDA) - Requires one available USB port.


    MultiVision Sensors

        Range Resolution
    54-42-80 LEL combustible gas / Oxygen (02) 0-100% LEL 1% LEL
    54-42-90 LEL combustible gas / Oxygen (02) / Carbon Monoxide (CO) 1-30% Vol 0.1%
    54-42-01 LEL combustible gas / Oxygen (02) / Hydrogen Sulfide (H2S) 0-1000 ppm 1 ppm
    54-42-02 LEL combustible gas / Oxygen (02) / Carbon Monoxide (CO) / Hydrogen Sulfide (H2S) 0-200 ppm 1 ppm
    54-42-101


    MultiVision replacement set of 4 sensors. O2, LEL, CO and H2S.
    This is the most economical way of replacing the 4-sensor set after 2 years, rather than ordering the sensors separately.


    MultiVision 54-40-90 Oxygen Sensor for Biosystems MultiVision

    MultiVision 54-40-01 CO Sensor for Biosystems MultiVision

    MultiVision 54-40-02 H2S Sensor for Biosystems MultiVision

    54-40-90 MultiVision Oxygen Sensor 54-40-01 MultiVision CO Sensor 54-40-02 MultiVision H2S Sensor

     

    MultiVision Remote Sampling Accessories

    Part No.
    Description
    xx54-41-001  MuIti Vision Calibration Adapter
    54-41-005
    MuIti Vision Remote Sampling Adapter Manual sample draw
    54-41-003
    MuIti Vision Remote Sampling Adapter (Internal pump). Includes pump activation magnet. Requires internal um to be installed in MuItiVision
    54-41-006
    MuIti Vision Internal Pump Upgrade. Must be returned to Biosystems service department. This part number includes labor charges for upgrade. Does not include freight.
    54-41-007
    MuIti Vision Manual sample draw kit. Includes adapter, squeeze bulb, 10' of tubing and sample probe assembly.
    54-05-A0403
    Sample robe assembly. Does not include tubing, squeeze bulb, or sample draw adapter
    54-05-A0405
    Sample probe assembly with 11.5-inch stainless-steel probe tube. Does not include tubing squeeze bulb, or sample draw / calibration adapter

    MultiVision Miscellaneous Accessories

    Part No. Description
    13-230
    MuItiVision Reference Manual
    13-232
    MuItiVision Quick Reference Card
    22-165
    MuItiVision training video
    22-166
    MuItiVision training CD-ROM
    54-41-004B
     Rubber Boot. Black
    54-41-004R
     MultiVision MuItiVision Rubber Boot. Red
    54-41-004Y
     MuItiVision Rubber Boot. Yellow
     

    MuItiVision Charging, Datalogging & Communication Accessories

    Part No. Description
    54-41-002
    MuItiVision Slip -in fast charger (110 VAC). Includes "wall cube" supply.
    54-41-01 0
    MuItiVision Slip-in fast charger (12 VDC). Includes "cigarette lighter" style adapter, and vehicle mounting hardware.
    54-41-011
    MuItiVision Five instrument 110 VAC slip-in multi-charger. Includes power supply
    35-0488
    MuItiVision Alkaline Battery Pack
    35-0489
    MuItiVision NiMH Battery Pack
    54-41-016
    MuItiVision PC programming kit. Used for instrument configuration only. Includes software and serial interface cable. MuItiVision Datalogger and infrared communication (IrDA) upgrade.
    54-41-014
    Must be returned to Biosystems service department. Includes labor charges for upgrade. Does not include freight.
    54-41-008
    MuItiVision BioTrak Download software. Requires MuItiVision datalogging option be installed. Computer must support infrared communication IrDA to download.
    54-26-0605S
    Infrared communication device Serial - IrDA - Requires one available PC serial port.
    54-26-0605U
    Infrared communication device (USB - IrDA) - Requires one available USB port.
     

    MuItiVision Calibration Material & Carrying Cases

    Part No. Description
    54-41-012
    MuItiVision Case for Value Pack. Foam-lined case, with room for 1 compact sized calibration gas cylinder.
    35-0259
    MuItiVision Case for Confined Space Kit. Foam-lined, waterproof Pelican style case with room for one standard sized calibration as cylinder
    54-41-013
    MuItiVision Calibration kit. Includes foam-lined carrying case with room for up to three cylinders of calibration as. Kit contains 12-023 regulator and other fittings. Kit does not include gas.
    54-41-V9045
    MuItiVision Value Pack "Make-up" Kit. Includes Value Pack case with 54-9045E calibration gas and 12-022 economy regulator. For use with 02 / LEL and 02 / LEL / CO configurations.
    54-41-V9047
    MuItiVision Value Pack "Make-up" Kit. Includes Value Pack case with 54-9047E calibration gas and 12-023 regulator. For use with 02 / LEL / H2S configurations.
    54-41-V9049
    MuItiVision Value Pack "Make-up" Kit. Includes Value Pack case with 54-9049E calibration gas and 12-023 regulator. For use with 02 / LEL / CO / H2S configurations.
    xx54-41-001
    xMuItiVision Calibration Adapter


    WARNING! Honeywell Analytics - Biosystems equipment should only be used in conjunction with the manufacturer's instructions.
    Failure to follow such instructions could result in serious injury or fatality.


    Multi Vis[on Navigation Button to Kit Options Multi Vision Navigation Button to Specifications Multi Vision Navigation Button to Sensors Multi Vision Navigation Button to  Accessories Multi Vision Navigation Button to Sampling Accessories Multi Vision Navigation Button to IQ Dock Multi Vision Navigation Button to Calibration Gases Multi Vision Navigation Button to  Caibration Kits& Cases

    Return to Top

     

    Return to Brandt Instruments
    For more information  Email Mail
    Brandt Instruments, Inc. 
        18568 Oak Grove Parkway 
        Prairieville, LA  70769 
    1-800-337-6291  
    Phone: 225-673-6776
        Fax: 225-673-6725
     

    Visa, MC, AmEx, Discover Cards

    Copyright © 2002-2017 Brandt Instruments, Inc.