Biosystems
Index
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Size: | 6" x 3.4" x 2.5" (15 x 8.6 x 6.4 cm) |
| Weight: | 20 oz. (570 g) |
| Intrinsic Safety: | UL Classified
for Class 1 Division 1 Groups A,B,C,D Hazardous Locations. Other certifications pending |
| Durability: | Meets IPX5/IPX7 water standard |
| Display: | Oversized 2" x 1.5" LCD display. |
| Audible Alarm: | Loud warbling, two-tone alarm rated at 92 dBA at one foot. |
| Visual Alarm: | Bright red LED alarm. |
| Display Backlight: | Activates with MODE button. |
| Controls: | One-button automatic calibration. |
| Housing: | Chrome metal-plated, RFI resistant ABS with RFI immunity to 40 V/m. |
| Battery Options: | Alkaline or rechargeable NiMH (Nickel Metal Hydride) battery packs. |
| Battery Life (diffusion): | 20 hours NiMH, 16 hours Alkaline. |
| Battery Life with Pump: | 16 hours NiMH, 12 hours Alkaline. |
Standard Accessories: Each MultiVision detector is shipped complete with standard accessories including belt clip, calibration adapter and tubing, reference manual, quick reference card, and training CD-ROM.
MultiVision detectors are also available as Confined Space Kits and Value Pack Kits.Alkaline MultiVision detectors come with an alkaline battery pack and a set of three AA disposable batteries. Rechargeable MultiVision detectors include a Nickel Metal Hydride (NiMH) battery pack and slip-in charger cradle.
Confined Space Kits include all standard accessories plus an all-in-one large cylinder of calibration gas (58 or 103 liters), fixed flow regulator and calibration adapter all in a waterproof "pelican-style" carrying case. Value Pack Kits include an alkaline MultiVision detector with standard accessories plus large all-in-one small cylinder of calibration gas (34 liters), fixed flow regulator and calibration adapter all in a hard-shell carrying case.
.
|
DESCRIPTION
|
MultiVision
Confined Space Gas Detector Part Number |
||||
| Alkaline
MultiVision |
Rechargeable
MultiVision NiMH |
MultiVision
Value Pack |
MultiVision
Alkaline CSK |
MultiVision
NiMH CSK |
|
| MultiVision with LEL / O2 sensors | 54-40-30000A | 54-40-30000N | 54-40-30000AV | 54-40-30000AC | 54-40-30000NC |
| MultiVision with LEL / O 2 / CO sensors | 54-40-30100A | 54-40-30100N | 54-40-30100AV | 54-40-30100AC | 54-40-30100NC |
| MultiVision with LEL / O2 / H2S sensors | 54-40-30200A | 54-40-30200N | 54-40-30200AV | 54-40-30200AC | 54-40-30200NC |
| MultiVision with LEL / O2 / CO / H2S sensors | 54-40-30102A | 54-40-30102N | 54-40-30102AV | 54-40-30102AC | 54-40-30102NC |
| Pump | Allows the user to switch automatically between sample draw and diffusion mode by attaching and detaching the sample draw adapter. |
| Datalogging | Enables the MultiVision to record and download measurements. Necessary to order to be IQ-Dock compatible. Download software must be purchased separately. Computer must support infrared communication (IrDA) to download. |
| 54-41-008 | MultiVision BioTrak Download Software |
| 54-26-0605 | Infrared communication device. Specify serial (S) or USB (U) Requires one available PC serial or USB port. |
![]() |
![]() |
|
MultiVision
Confined Space Kit
|
MultiVision
Meters with Protective Boots
|
| Part No. | Description |
|
54-41-004B
|
MultiVision
Rubber Boot. Black
|
|
54-41-004R
|
MultiVision
Rubber Boot. Red
|
|
54-41-004Y
|
MultiVision
Rubber Boot. Yellow
|
|
54-41-007
|
MultiVision
Manual Sample draw kit. Includes adapter, squeeze bulb, 10'
of tubing.
|
|
54-41-008
|
MultiVision
BioTrak Download software. Requires MultiVision datalogging
option be installed. Computer must support infrared communication
IrDA to download.
|
|
54-26-0605S
|
Infrared
communication device Serial - IrDA - Requires one available
PC serial port.
|
|
54-26-0605U
|
I
Infrared communication device (USB - IrDA) - Requires one available
USB port.
|
| Range | Resolution | ||
| 54-42-80 | LEL combustible gas / Oxygen (02) | 0-100% LEL | 1% LEL |
| 54-42-90 | LEL combustible gas / Oxygen (02) / Carbon Monoxide (CO) | 1-30% Vol | 0.1% |
| 54-42-01 | LEL combustible gas / Oxygen (02) / Hydrogen Sulfide (H2S) | 0-1000 ppm | 1 ppm |
| 54-42-02 | LEL combustible gas / Oxygen (02) / Carbon Monoxide (CO) / Hydrogen Sulfide (H2S) | 0-200 ppm | 1 ppm |
| 54-42-101 |
|
||
![]() |
|
|
| 54-40-90 MultiVision Oxygen Sensor | 54-40-01 MultiVision CO Sensor | 54-40-02 MultiVision H2S Sensor |
| Part No. |
Description
|
| xx54-41-001 | MuIti Vision Calibration Adapter |
|
54-41-005
|
MuIti
Vision Remote Sampling Adapter Manual sample draw
|
|
54-41-003
|
MuIti
Vision Remote Sampling Adapter (Internal pump). Includes pump activation
magnet. Requires internal um to be installed in MuItiVision
|
|
54-41-006
|
MuIti
Vision Internal Pump Upgrade. Must be returned to Biosystems service
department. This part number includes labor charges for upgrade.
Does not include freight.
|
|
54-41-007
|
MuIti
Vision Manual sample draw kit. Includes adapter, squeeze bulb, 10'
of tubing and sample probe assembly.
|
|
54-05-A0403
|
Sample
robe assembly. Does not include tubing, squeeze bulb, or sample
draw adapter
|
|
54-05-A0405
|
Sample
probe assembly with 11.5-inch stainless-steel probe tube. Does not
include tubing squeeze bulb, or sample draw / calibration adapter
|
| Part No. | Description |
|
13-230
|
MuItiVision
Reference Manual
|
|
13-232
|
MuItiVision
Quick Reference Card
|
|
22-165
|
MuItiVision
training video
|
|
22-166
|
MuItiVision
training CD-ROM
|
|
54-41-004B
|
Rubber
Boot. Black
|
|
54-41-004R
|
MultiVision
MuItiVision Rubber Boot. Red
|
|
54-41-004Y
|
MuItiVision
Rubber Boot. Yellow
|
| Part No. | Description |
|
54-41-002
|
MuItiVision
Slip -in fast charger (110 VAC). Includes "wall cube" supply.
|
|
54-41-01
0
|
MuItiVision
Slip-in fast charger (12 VDC). Includes "cigarette lighter" style
adapter, and vehicle mounting hardware.
|
|
54-41-011
|
MuItiVision
Five instrument 110 VAC slip-in multi-charger. Includes power supply
|
|
35-0488
|
MuItiVision
Alkaline Battery Pack
|
|
35-0489
|
MuItiVision
NiMH Battery Pack
|
|
54-41-016
|
MuItiVision
PC programming kit. Used for instrument configuration only. Includes
software and serial interface cable. MuItiVision Datalogger and
infrared communication (IrDA) upgrade.
|
|
54-41-014
|
Must
be returned to Biosystems service department. Includes labor charges
for upgrade. Does not include freight.
|
|
54-41-008
|
MuItiVision
BioTrak Download software. Requires MuItiVision datalogging option
be installed. Computer must support infrared communication IrDA
to download.
|
|
54-26-0605S
|
Infrared
communication device Serial - IrDA - Requires one available PC serial
port.
|
|
54-26-0605U
|
Infrared
communication device (USB - IrDA) - Requires one available USB port.
|
| Part No. | Description |
|
54-41-012
|
MuItiVision
Case for Value Pack. Foam-lined case, with room for 1 compact sized
calibration gas cylinder.
|
|
35-0259
|
MuItiVision
Case for Confined Space Kit. Foam-lined, waterproof Pelican style
case with room for one standard sized calibration as cylinder
|
|
54-41-013
|
MuItiVision
Calibration kit. Includes foam-lined carrying case with room for
up to three cylinders of calibration as. Kit contains 12-023 regulator
and other fittings. Kit does not include gas.
|
|
54-41-V9045
|
MuItiVision
Value Pack "Make-up" Kit. Includes Value Pack case with 54-9045E
calibration gas and 12-022 economy regulator. For use with 02 /
LEL and 02 / LEL / CO configurations.
|
|
54-41-V9047
|
MuItiVision
Value Pack "Make-up" Kit. Includes Value Pack case with 54-9047E
calibration gas and 12-023 regulator. For use with 02 / LEL / H2S
configurations.
|
|
54-41-V9049
|
MuItiVision
Value Pack "Make-up" Kit. Includes Value Pack case with 54-9049E
calibration gas and 12-023 regulator. For use with 02 / LEL / CO
/ H2S configurations.
|
|
xx54-41-001
|
xMuItiVision Calibration Adapter |
|