Brandt Intruments: Sperian Instruments, Biosystems Gas Detectors,now Honeywell Analytics, MultiPro, ToxiPro, PhD6, calibration gas,, PosiChek3 SCBA tester

Representing Biosystems by Honeywell Analytics

Biosystems, Sperian Instruments, Honeywell, gas detectors, MultiPro, PhD6, ToxiPro, ToxiLTD, IQ Docking Stations, PosiChek3 SCBA Testing, calibration gas


Biosystems IQ Management System Software

IQ Docking Stations: Automated Bump Testing, Calibration,
Datalogging & Diagnostics
of PhD6, MultiPro & ToxiPro Detectors

From Sperian Instruments now Honeywell Analytics


home » biosystems index » Biosystems IQ Management System



                                                         

Biosystems Index
.. Single Gas Portables..
.. Multi-Gas Portables

..   ..MultiPro
...   .MultiVision
...   .PhD6
...   .Cannonball3
.. Fixed Point Systems
.. Air Purification Panel
. .Respirator Test Bench
. .Cal Gas & Accessories
. .Application Notes

The Honeywell | Biosystems IQ Docks™ are fully automated bump test, calibration, meter diagnostics and data download centers for gas detectors. Just place the meter in the dock, the IQ docking station does the rest.

The IQ Docks automatically identify the instrument, check the battery, then perform a bump test. If the detector fails the bump test, the IQ automatically conducts a full span calibration. It then tests the audible, visible and vibrating (if available) alarms and other parameters before downloading the instrument data.

Calibration finishes in two minutes versus the 3-5 minutes it would take to do manually, and bump testing takes about 22 seconds versus the approximate two minutes per instrument when completed manually. Reduces cost of calibration gas to your company by more than 60% annually.

The Biosystems IQ Management System software is hosted on the user's own database and is compatible with the IQ Force, PHD6™ Multi-Gas Detector, IQ6™ Docking Station, ToxiPro® Single-Gas Detector IQ Express™ Docking Station, MultiPro™ Multi-Gas Detector and MultiPro IQ Express™ Docking Station.

The IQ Management System puts safety back in the user's hands by providing the data that the user wants and can use, without slowing them down with excess information that is not needed. It allows the user to configure and customize reports and analyses rather than conforming to a "one size fits all" model. Through the networkable IQ Dock and system software, obtain full visibility to information about detector performance, compliance and trending. The IQ Management System is fully automated. Users can receive automatic emails with configured alarm levels, increased security through password protection and increased workforce productivity by having instruments automatically ready to use at shift changes.


biosystems MultiPro IQ Express Automated Calibraton & Bump Station


Biosystems IQ6 Automated Calibration Station with Callibration Gas , PhD6 Meter


Biosystems Toxi IQ Express Automated Calibraton & Bump Station

MultiPro IQ Express
IQ6 Automated
Calibration & Bump Station
Toxi IQ Express

IQ Dock™ Bump Test & Calibration Stations

 
Automated Tests
Configuration Options
Checks 8-12 different performance functions
depending on the docking station
  • Instrument identification
  • Battery test. useage
  • Alarm tests (audible, visible, vibration)
  • Security settings
  • Ready / fault indication
  • Bump test 4 gases in under 45 seconds (O2, LEL, CO, H2S)
  • Calibration (if needed) in under 2 minutes
  • Sensor health status
  • Safety incident history
  • Gas exposure levels
  • Cal gas consumption
  • Maintains records of instrument and calibration data
  • Provides clear, easy-to-read reports
  • Standalone calibration station
  • Connect to PC via USB or Ethernet for enhanced control over calibration and data acquisition during testing (optional)
  • Ethernet capable docks can send e-mail to a specified address when a fault is detected
  • Docking station software allows the user to customize the instrument's settings and calibration gas setup
  • 2 port docks can process a meter using one multi-gas and one single component cylinder or two single component cylinders
  • 4-port docks can process a meter using one multi-gas cylinder and three single component cylinders or four single component cylinders

IQ Management System Product Options

   Detectors    IQ Docking Station Configurations
  IQ Force
  • IQ Force™ Four-Gas Detector and IQ Force™ Dock
  • IQ Force rugged IP65/67 multi-gas detector monitors O2, LEL, CO and H2S
  • Fully automated bump test and calibration station performs up to 12 critical tests
  • Can connect up to four IQ Force stations to a single gas supply
  • Remote e-mailing feature
  • Connects to PC via USB or Ethernet to download data
  MultiPro
  • MultiPro™ Four-Gas Detector and MultiPro IQ Express™ Dock
  • Economical MultiPro which monitor O2, LEL, CO and H2S
  • Fully automated bump test and calibration station performs up to eight critical tests
  • Connects to PC via USB or Ethernet to download data
  PhD6  


  • PhD6™ Six-Gas Detector and IQ6™ Dock
  • Value-packed PHD6 monitors six gasses simultaneously; optional PID and IR sensors monitor VOCs and CO2
  • Fully automated bump test and calibration station performs up to twelve critical tests
  • Comes standard with four configurable gas ports
  • Connects to PC via USB or Ethernet WAN to download data
   Toxi Pro
  • ToxiPro® Single-Gas Detectors and the Toxi IQ Express™ Dock
  • Fully automated bump test and calibration station performs up to eight critical tests
  • Connects to PC via Ethernet WAN to download data
  • Can connect up to four IQ Express stations to a single gas supply
  • Link each detector to a person
 


     * Note:
Required demand flow regulators, calibration gas & Honeywell Analytics-Biosystems meters sold separately


 

Biosystems IQ6 Docking Station with PhD6 Meter &  Cal Gas

IQ6 Docking Station with PhD6 Meter
& Calibration Gas Cylinder


WARNING!
Honeywell Analytics - Biosystems equipment should only be used in conjunction with the manufacturer's instructions.
Failure to follow such instructions could result in serious injury or fatalities.

Back-to_Topo Icon

Return to Biosystems Index Page

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards

Copyright © 2002-2017 Brandt Instruments, Inc.