Biosystems IQ Management System Software

IQ Docking Stations for Automated Bump Testing, Calibration,
Datalogging & Diagnostics
of PhD6, MultiPro & ToxiPro Detectors

From Sperian Instruments now Honeywell Analytics


home » biosystems index » Biosystems IQ Management System



                                                         

Biosystems Index
.. Single Gas Portables..
.. Multi-Gas Portables

..   ..MultiPro
...   .MultiVision
...   .PhD6
...   .Cannonball3
.. Fixed Point Systems
.. Air Purification Panel
. .Respirator Test Bench
. .Cal Gas & Accessories
. .Application Notes

The Biosystems IQ Management System software is hosted on the user's own database and is compatible with the PHD6™ Multi-Gas Detector, IQ6™ Docking Station, ToxiPro® Single-Gas Detector, ToxiLtd® Single-Gas Detector, IQ Express™ Docking Station, MultiPro™ Multi-Gas Detector and MultiPro IQ Express™ Docking Station.

The IQ Management System puts safety back in the user's hands by providing the data that the user wants and can use, without slowing them down with excess information that is not needed. It allows the user to configure and customize reports and analyses rather than conforming to a "one size fits all" model.

Through the networkable IQ Dock and system software, you obtain full visibility to information about detector performance, compliance and trending. IQ Management System is fully automated. Users receive automatic emails with configured alarm levels, increased security through password protection and increased workforce productivity by having instruments automatically ready to use at shift changes.

The Biosystems IQ Express Docks are fully automated bump test, calibration, meter diagnostics and data download centers for the gas detectors. Just place the meter in the dock, the IQ docking station does the rest.

The IQ Dock automatically identifies the instrument, checks the battery, then performs a bump test. If the detector fails the bump test, the IQ automatically conducts a full span calibration of the detector. It then tests the audible, visible and vibrating (if available) alarms before downloading the instrument data.

Reduce downtime with IQ Management System's quick calibration and bump testing. Calibration finishes in two minutes versus the 3-5 minutes it would take to do manually, and bump testing now takes 22 seconds versus the approximate two minutes per instrument when completed manually. Reduces cost of calibration gas to your company by more than 60% annually.

biosystems MultiPro IQ Express Automated Calibraton & Bump Station


Biosystems IQ6 Automated Calibration Station with Callibration Gas , PhD6 Meter


Biosystems Toxi IQ Express Automated Calibraton & Bump Station

Biosystems MultiPro IQ Express

Biosystems IQ6 Automated
Calibration & Bump Station

Biosystems Toxi IQ Express

IQ6 Express Dock™ Features

 
Automated Tests
Configuration Options
  • Checks more than 12 different performance functions
  • Instrument identification
  • Battery test
  • Alarm tests (audible, visible, vibrating
  • Ready / fault indication
  • Bump test 4 gases in under 45 seconds (O2, LEL, CO, H2S)
  • Calibration (if needed) in under 2 minutes (O2, LEL, CO, H2S)
  • Maintains records of instrument and calibration data
  • Provides clear, easy-to-read reports
  • Standalone calibration station
  • Connect to PC via USB or Ethernet for enhanced control over calibration and data acquisition during testing (optional)
  • Ethernet capable docks can send e-mail to a specified address when a fault is detected
  • Docking station software allows the user to customize the instrument's settings and calibration gas setup
  • 2 port docks can process a meter using one multi-gas and one single component cylinder or two single component cylinders
  • 4-port docks can process a meter using one multi-gas cylinder and three single component cylinders or four single component cylinders

IQ Management System Product Options

   Detectors    IQ Docking Station Configurations
   PhD6
  • PhD6™ Six-Gas Detector and IQ6™ Dock Value-packed PHD6 monitors six gasses simultaneously; optional PID and IR sensors monitor VOCs and CO2
  • Fully automated bump test and calibration station performs up to twelve critical tests
  • Comes standard with two configurable gas ports; four-port model is available
  • Connects to PC via USB or Ethernet WAN to download data
   MultiPro
  • MultiPro™ Four-Gas Detector and MultiPro IQ Express™ Dock Economical MultiPro monitors O2, LEL, CO and H2S
  • Fully automated bump test and calibration station performs up to eight critical tests
  • Connects to PC via USB or Ethernet to download data
   Toxi Pro & ToxiLtd
  • ToxiPro® & ToxiLtd® Single-Gas Detectors and IQ Express™ Dock Single-gas detectors in disposable (ToxiLtd) or field-replaceable (ToxiPro) units monitor confined space gases
  • Fully automated bump test and calibration station performs up to eight critical tests Connects to PC via Ethernet WAN to download data
  • Can connect up to four IQ Express stations to a single gas supply
  • Link each detector to a person and have the knowledge to keep people safe
 


     * Note:
Required demand flow regulators, calibration gas & Honeywell Analytics-Biosystems meters sold separately


 

Biosystems IQ6 Docking Station with PhD6 Meter &  Cal Gas

IQ6 Docking Station with PhD6 Meter
& Calibration Gas Cylinder


WARNING!
Honeywell Analytics - Biosystems equipment should only be used in conjunction with the manufacturer's instructions.
Failure to follow such instructions could result in serious injury or fatalities.

Back-to_Topo Icon

Return to Biosystems Index Page

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards

Copyright © 2002-2012 Brandt Instruments, Inc.

Notice: This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures. Brandt Instruments, Inc. reserves the right to make any changes to information, features, and specifications of any product without notice. Brandt Instruments, Inc. has made every effort to ensure the accuracy of information displayed on this web site, however, Brandt Instruments, Inc. is not responsible for typographical errors appearing on this web site. Price and availability information is subject to change without notice.