Biosystems IQ6 Express Dock™

Automated Docking Station for Bump Testing, Calibration,
Datalogging & Diagnostics
of PhD6 Detectors
From Sperian Instruments now Honeywell Analytics


home » biosystems index » Biosystems IQ6 Express Dock








Biosystems Index
.. Single Gas Portables..
.. Multi-Gas Portables

..   ..MultiPro
...   .MultiVision
...   .PhD6
...   .Cannonball3
.. Fixed Point Systems
.. Air Purification Panel
. .Respirator Test Bench
. .Cal Gas & Accessories
. .Application Notes

Sperian Biosystems IQ6 Automated Calibration Station with Callibration Gas , PhD6 Meter

Sperian Biosystems IQ6 Automated
Calibration & Bump Station

The Biosystems IQ6 Express Dock is a fully automated bump test, calibration, meter diagnostics and data download center for the PhD6 gas detector. Just place the meter in the dock, the IQ6 docking station does the rest.

It can reduce calibration gas use by up to 60% and reduce labor expenses by cutting down on the time needed to perform calibrations.

The IQ6 Dock automatically identifies the instrument, checks the battery, then performs a bump test. If the detector fails the bump test, the IQ6 automatically conducts a full span calibration of the detector. It then tests the audible, visible and vibrating (if available) alarms before downloading the instrument data.

Reports are generated using the Database Management Pro software.

IQ6 Express Dock™ Features

 
Automated Tests
Configuration Options
  • Checks more than 12 different performance functions
  • Instrument identification
  • Battery test
  • Alarm tests (audible, visible, vibrating
  • Ready / fault indication
  • Bump test in under 45seconds (O2, LEL, CO, H2S)
  • Calibration (if needed) in under 2 minutes (O2, LEL, CO, H2S)
  • Maintains records of instrument and calibration data
  • Provides clear, easy-to-read reports
  • Standalone calibration station
  • Connect to PC via USB or Ethernet for enhanced control over calibration and data acquisition during testing (optional)
  • The Ethernet capable docks can send e-mail to a specified address when a fault is detected
  • Docking station software allows the user to customize the instrument's settings and calibration gas setup
  • 4-port dock can process a PhD6 using one multi-gas cylinder and three single component cylinders or four single component cylinders

IQ6 Docking Station Configurations

Part Number Description
54-43-9400N Ethernet ready IQ6 Dock with fresh air port plus 4 calibration gas inlet ports, software, installation disks and manuals
12-061* Demand flow regulator (one required for each cylinder of gas used)
54-05-001 Calibration gas tank holder
 
* Note: Honeywell Analytics-Biosystems PhD6 detectors, demand flow regulators, calibration gas, cases and other and accessories sold separately

 

Biosystems IQ6 Docking Station with PhD6 Meter &  Cal Gas

IQ6 Docking Station with PhD6 Meter
& Calibration Gas Cylinder


WARNING!
Honeywell Analytics - Biosystems equipment should only be used in conjunction with the manufacturer's instructions.
Failure to follow such instructions could result in serious injury or fatalities.

Back-to_Topo Icon

Return to Biosystems Index Page

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards

Copyright © 2002-2011 Brandt Instruments, Inc.