Biosystems Single &
Multi-Component Calibration
|
||
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Part # |
Combustible gas |
LEL |
CO |
H2S |
Shelf Life |
Cylinder Volume |
|
54-9041
|
Methane | 50% LEL | 50 ppm | - |
5 years
|
103 liters
|
|
54-9043*
|
Methane | 50% LEL | 50 ppm | 25 ppm |
1 year
|
58 liters
|
|
54-9042E
|
Propane equivalent | 50% LEL | 50 ppm | - |
5 years
|
103 liters
|
|
54-9045E*
|
Propane equivalent | 50% LEL | 50 ppm | - |
5 years
|
34 liters
|
|
54-9044E**
|
Propane equivalent | 50% LEL | 50 ppm | 25 ppm |
1 year
|
58 liters
|
|
54-9049E**
|
Propane equivalent | 50% LEL | 50 ppm | 25 ppm |
1 year
|
34 liters
|
|
54-9048E
|
Propane equivalent | 50% LEL | - | 25 ppm |
1 year
|
58 liter
|
|
54-9047E
|
Propane equivalent | 50% LEL | - | 25 ppm |
1 year
|
34 liter
|
|
54-9070E
|
Pentane equivalent | 50% LEL | 50 ppm | - |
5 years
|
103 liters
|
|
54-9046E
|
Pentane equivalent | 50% LEL | 50 ppm | 25 ppm |
1 year
|
58 liters
|
|
54-9071E*
|
Pentane equivalent | 50% LEL | 50 ppm | - |
5 years
|
34 liters
|
Note: Shelf life figures from date of manufacture * Only for use with 12-022 regulator ** Not for use with CO+ or Toxi sensors |
||||||
|
||||||
|
Part #
|
Gas type
|
Concentration | Shelf life | Volume | ||
|
54-9031
|
LEL Methane | 50% LEL | 5 years | 103 liters | ||
|
54-9032E
|
LEL Propane equivalent | 50% LEL | 5 years | 103 liters | ||
|
54-9068E
|
LEL Pentane equivalent | 50% LEL | 5 years | 103 liters | ||
|
54-9066
|
LEL Hydrogen (H2) | 59% LEL | 5 years | 103 liters | ||
|
54-9072
|
LEL - JP8 Surrogate | 50% LEL | 5 Years | 103 liters | ||
|
54-9033
|
CO Carbon monoxide | 50 ppm | 5 years | 103 liters | ||
|
54-9036*
|
CO Carbon monoxide | 50 ppm | 5 years | 34 liters* | ||
|
54-9034
|
H2S Hydrogen sulfide | 25 ppm | 1 year | 58 liters | ||
|
54-9057
|
H2S Hydrogen sulfide | 25 ppm | 1 year | 34 liters | ||
|
54-9037
|
SO2 Sulfur dioxide | 10 ppm | 1 year | 58 liters | ||
|
54-9058
|
SO2 Sulfur dioxide | 10 ppm | 1 year | 34 liters | ||
|
54-9051**
|
NH3 Ammonia** | 50 ppm | 1 year | 58 liters | ||
|
54-9061**
|
NH3 Ammonia** | 50 ppm | 1 year | 34 liters | ||
|
54-9052
|
Cl2 Chlorine | 5 ppm | 8 months | 58 liters | ||
|
54-9076
|
Cl2 Chlorine | 10 ppm | 8 months | 58 liters | ||
|
54-9055
|
NO Nitric oxide | 30 ppm | 6 months | 58 liters | ||
|
54-9056
|
NO2 Nitrogen dioxide | 5 ppm | 6 months | 58 liters | ||
|
54-9059
|
NO2 Nitrogen dioxide | 5 ppm | 6 months | 34 liters | ||
|
54-9054
|
HCN Hydrogen cyanide | 10 ppm | 1 year | 58 liters | ||
|
54-9053
|
HCl Hydrogen chloride | 10 ppm | 1 year | 58 liters | ||
|
54-9065
|
PH3 Phosphine | 5 ppm | 6 months | 58 liters | ||
|
54-9073
|
PH3 Phosphine | 5 ppm | 6 months | 34 liters | ||
|
54-9064
|
H2 Hydrogen | 100 ppm | 5 years | 103 liters | ||
|
54-9035
|
N2 Nitrogen | 99.9% | 5 years | 103 liters | ||
|
54-9039
|
O2 Oxygen (Zero air) | 20.9% | 5 years | 103 liters | ||
|
54-9062
Chlorine 5 ppm in 34 liter cylinder has been discontinued. |
||||||
|
||||||
| Part # |
Description
|
|||||
| 12-022 | Regulator,
1.0 liter per min flow Only for use with 54-9036, 54-9045E and 54-9071E calibration gas cylinders |
|||||
| 12-023 | Regulator, standard service 1.0 liter per min flow | |||||
| 12-025 | Regulator, ammonia service, 1.0 liter per min flow | |||||
| 12-030 | Regulator, standard service, 1.0 liter per min flow with on/off knob | |||||
| 12-061 | Demand flow regulator, standard service, 0 - 3 liter per min flow | |||||
| 35-0380 | AirCheck 3000 PSI regulator, 1.0 liter per min with CGA346 hand-wheel coupling. Can be used in conjunction with a gas detector to conduct air quality check on breathing air cylinders. | |||||
|
12-039 Demand Flow Regulator |
12-023 Regulator
|
54-49-200
Biosystems MultiPro |
|
54-05-A0403 Sample Probe Assembly |
Tubing
Assembly with Squeeze Bulb and |
|
WARNING!
Honeywell Analytics - Biosystems equipment should only be used in
conjunction with the manufacturer's instructions.
Failure
to follow such instructions could result in serious injury or fatality.
|