Biosystems
Index |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||
Sensor Configuration |
ToxiPro Part # |
||
Oxygen O2 |
54-45-90VD
|
||
Carbon Monoxide CO |
54-45-01VD
|
||
CO-H, reduced sensitivity to H2 |
54-45-19VD
|
||
Hydrogen Sulfide H2S |
54-45-02VD
|
||
Sulfur Dioxide SO2 |
54-45-03VD
|
||
Hydrogen Cyanide HCN |
54-45-10VD
|
||
Nitrogen Dioxide NO2 |
54-45-09VD
|
||
Phosphine PH3 |
54-45-13VD
|
||
Chlorine (specific) Cl2 † |
54-45-18VD
|
||
Ammonia NH3 |
54-45-21VD
|
||
Meters come standard with datalogging and internal vibrating alarm. Accessories include: calibration/sample draw adapter, reference manual, quick reference card. |
|||
† The specific Cl2 sensors are designed for the target gas only |
Code After Part Numbers: | |
Description |
Code
|
Vibrating alarm - internal vibrating alarm which works in tandem with audible and visual alarms |
V
|
Datalogging - enables the ToxiPro to record and download measurements and time history data. Computer must support IrDA to download. |
D
|
IQ Express Station with ToxiPro Meters |
IQ Express Station with Meter & Calibration Gas |
4-Position IQ Express Calibration Station |
|
|
Part
#
|
Sensor
Description
|
Range
|
Resolution |
54-47-90 | O2 Oxygen (2 Years) | 0-30% Vol | 0.1% |
54-47-01 | CO Carbon Monoxide | 0-1000 ppm | 1 ppm |
54-47-05 | CO+
Dual Purpose CO/H2S Provides a non-specific readout for CO & H2S |
CO:
0-1000 ppm H2S: 0-200 ppm |
1 ppm |
54-47-19 | CO-H CO Minus, reduced sensitivity to H2 | 0-1000 ppm | 1 ppm |
54-47-02 | H2S Hydrogen Sulfide | 0-200 ppm | 1 ppm |
54-47-03 | SO2 Sulfur Dioxide | 0-25 ppm | 0.1 ppm |
54-47-15 | SO2-Ext Sulfur Dioxide extended range | 0-100 ppm | 1 ppm |
54-47-21† | NH3 Ammonia | 0-100 ppm | 1 ppm |
54-47-18† | Cl2 Chlorine (Specific) | 0-50 ppm | 0.1 ppm |
54-47-09† | NO2 Nitrogen Dioxide | 0-20 ppm | 0.1 ppm |
54-47-10† | HCN Hydrogen Cyanide | 0-100 ppm | 0.2 ppm |
54-47-13 | PH2 Phosphine | 0-10 ppm | 0.01 ppm |
†Note: Special reactive gas
calibration adapter and tubing required for proper calibration
*ClO2 sensors require a gas generator for calibration
ToxiPro O2 Sensor 54-47-90 |
ToxiPro H2S Sensor 53-47-02 |
ToxiPro CO Sensor 54-47-01 |
Terms for Instrument and Accessory Returns: |
NOTE: Any returns will incur the Honeywell 25% restocking fee on the list price of the item. To return any instruments or accessories you must request a Return Authorization number prior to returning anything to the factory for credit. This Return Authorization number must be prominently displayed on the outside of the shipping box. All products returned to Honeywell must be sent freight pre-paid, in new condition and in the original cartons with all unopened software, accessories and manuals. The sender is responsible for any carrier loss or damage. |
WARNING!
Honeywell - Biosystems equipment should only be used in conjunction
with the manufacturer's instructions.
Failure
to follow such instructions could result in serious injury or fatality.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|