Brandt Instruments Distributing BIOS, Dry Cal Definer 1020 Met Lab Precison Air Flow Calibrators (dry piston calibrator technology)
Brandt Instruments Distributing BIOS 
DryCal Met Lab Air Flow Calibrators

     
Bios DryCal Definer™ 1020
Met Lab Calibrator
500 SLM Piston Prover


                 Home » Bios
» Bios DryCal Definer 1020 Met Lab Primary Piston Prover

Bios DryCal Definer 1020 Met Lab Calibrator  In Use

 




Bios Definer 1020 Met Lab Calibrator
500 SLM Primary Piston Prover

The Bios DryCal Definer 1020 Met Lab series calibrator has a flow range from 5 to 500 liters per minute with an accuracy of ±0.25% of reading. It has up to ten times the volume of any other piston prover on the market. It does not require routine maintenance or consumable parts, just factory recalibration once each year.

Take flow measurements one at a time, or automate the process using hands-free Continuous or Burst modes. Select the number of flow measurements in the average, from 1 -100 measurements.

The portability of the Definer 1020, which weighs in at only 90 lbs., is a dramatic and welcome improvement over the cumbersome bell provers, labs have used in the past. The 1020 is a compact but powerful calibrator, featuring the patented proven DryCal® technology, a leader in flow calibration.

 


 Adobe Acrobat pdf format - Bios Definer 1020 Spec Sheet Bios Definer 1020 Spec Sheet

 

 

 

Bios Dry Cal Definer 1020 Met Lab Precision Piston Prover for gas flow measurements

 

 

 

Bios NVLAP Certification

MET LAB DEFINER 1020 OVERVIEW

Flow Range sL/min*
5 –500
Accuracy, 5-500 SL/Min
±0.25% of reading
Time per Measurement
5-100 seconds (approximate)
Weight
90 lbs / 41 kg
User Selectable Flow Units
Volumetric Flow
L/min, cf/min
Standard Flow
SL/min, scf/Min
Pressure
mmHg, PSI, kPa
Temperature
°C, °F
 

*Gas pressure of 760mmHg and a gas temperature of 25°Centigrade with Standardization temperature set to 0° Centigrade.


 

Proven DryCal Technology

MET LAB DEFINER 1020 SPECIFICATIONS

Data Cable 1 meter, for use with data port, Bios Optimizer™ software and PC serial port
Data Port RS-232 (Serial) for use with data cable & Bios Optimizer™ software
Flow Measurement Cell Integrated, allin-one design with no additional flow models
Flow Measurement Type Volumetric (primary by nature), Standardized
Flow Mode Suction and Pressure
Suitable Gases Non-corrosive, non-condensing, non-combustible gases. Humidity less than 70%, non-condensing
Inlet & Outlet Fittings 1 ½" Swagelok™ compression fitting
Power

External power module.
Input: 100-240 VAC, 1.6A (max), 50-60 Hz
Output: 12 VDC 3.0A

Pressure (Operating) 10-19.5 PSI (absolute)
Pressure Transducer 0-20 PSI (absolute), accuracy ±0.05%
FS (typical, ±0.05% (max)
Purge fittings ¼" Swagelok™ compression fittings
RoHS Compliant Yes
Storage Temperature 0-70° C
Temperature (Operating) 15-35° C
Temperature Sensor Accuracy ±0.03% (max), measured in the gas stream
Valve Operation Air supply: 80-100 PSI (not provided)
Fitting: ¼"
Swagelok™ compression fitting
Warranty 1 year

 

Back to Bios Index

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards

Copyright © 2002-2012 Brandt Instruments, Inc.

Notice: This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures. Brandt Instruments, Inc. reserves the right to make any changes to information, features, and specifications of any product without notice. Brandt Instruments, Inc. has made every effort to ensure the accuracy of information displayed on this web site, however, Brandt Instruments, Inc. is not responsible for typographical errors appearing on this web site. Price and availability information is subject to change without notice.