Brandt Instruments, representing Gasco Gas calibration & Bump Gas Gasco Non-Reactive Multiple Gas Mixtures, Carbon Monoxide, Methane, Pentane, Propane, Oxygen, Nitrogen - Calibration Gases for Confined Space Meters
   
Gasco Calibration & Bump Gas for Gas Detectors, IAQ Meters, environmental monitors
Nonreacxtive Single Calibration Gas Cylinders Reactive Multiple Calibration Gas Cylinders Accessories, Including Cases and Pressure Regulators for Gas Cylinders
Nonreactive Multiple Calibration Gas Cylinders Reactive Single Calibration Gas Cylinders Brandt Instruments Order Form for Calibration Gas & Accessories
Instrument Calibration Gas Mixtures
Nonreactive Multiple Gas Mixtures for Biosystems, ISC, MSA, Draeger, Dynamation, Gasctech, Lumidor, Bacharach, Quest
GASCO P/N
SUFFIX
CARBON MONOXIDE
METHANE
PENTANE
PROPANE
CARBON DIOXIDE
OXYGEN
BALANCE
GAS DETECTION
COMPANY
THEIR P/N
-300
250 PPM
50% LEL
       
AIR
BACHARACH
51-2969
-301
50 PPM
50% LEL
       
AIR
BIOSYSTEMS
54-9041
-302
50 PPM
   
50% LEL
   
AIR
BIOSYSTEMS
54-9042
-303E
50 PPM
1.62% = (50% LEL) Propane simulant
 
18%
NITROGEN
BIOSYSTEMS
54-9042E
-303  
50% LEL
     
17%
NITROGEN
DRAEGER
4557019
-304
100 PPM
50% LEL
       
AIR
DRAEGER
4594946
-305
100 PPM
 
30% LEL
     
AIR
DRAEGER
4594947
-306  
20% LEL
     
19%
NITROGEN
DYNAMATION
7800-010
-307
200 PPM
50% LEL
       
AIR
DYNAMATION
7800-016
-308
100 PPM
20% LEL
       
AIR
DYNAMATION
7800-018
-309
200 PPM
50% LEL
     
19%
NITROGEN
DYNAMATION
 
-310
100 PPM
50% LEL
     
19%
NITROGEN
ISC
1810-1246
-311
100 PPM
 
25% LEL
   
19%
NITROGEN
ISC
1810-1576
-312    
25% LEL
   
19%
NITROGEN
ISC
1810-1238
-313
100 PPM
20% LEL
       
AIR
LUMIDOR
GFV123
-314  
1.45% = (58% LEL) Pentane simulant
 
15%
NITROGEN
MSA
476304
-314A
60 PPM
1.45% = (58% LEL) Pentane simulant
 
15%
NITROGEN
   
-315
50 PPM
50% LEL
     
17%
NITROGEN
QUEST
54-145
-317
50 PPM
   
25% LEL
 
19%
NITROGEN
QUEST
54-145
-318
50 PPM
50% LEL
     
12.0%
NITROGEN
GASTECH
81-0155
-321
100 PPM
50% LEL
     
17.0%
NITROGEN
   
-322
50 PPM
 
50% LEL
     
AIR
500 PSIG MAXIMUM
 
-323E
50 PPM
1.25%= (50% LEL) Pentane simulant
 
18.0%
NITROGEN
BIOSYSTEMS
54-9070E
-325
35 PPM
 
10% LEL
    
18.0%
NITROGEN
   
-332
50 PPM
    
10% LEL HEXANE
  
12.0%
NITROGEN
500 PSIG MAXIMUM
  
-393  
50% LEL
     
18.0%
NITROGEN
    
-395
50 PPM
50% LEL
   
2.50%
12.0%
NITROGEN
   
-398
35 PPM
30% LEL
     
18.5%
NITROGEN
   
-399  
50% Vol.
   
35% Vol.
 
NITROGEN
500 PSIG MAXIMUM
 

Many More Three Gas Mixtures available upon request - Contact Brandt Instruments.
The above mixtures may be purchased in the following cylinder sizes:
CYLINDER SIZE
P/N PREFIX
 PRICE
10 LITER 10L-
$45.00
17 LITER 17L-
$32.00
34 LITER 34L-
$65.00
103 LITER 103L-
$120.00
221 LITER 221L-
$115.00
Note: The part number is determined by the cylinder size followed by the appropriate suffix.
Example: Gasco P/N 103L-301 is a 103 liter cylinder containing 50 ppm CO & 50% LEL Methane, balance Air.

Cylinder Specifications & Photos

Regulator Specifications & Photos

Pricing Effective January 2008. Subject to Change Without Notice.
Note: Many More Mixtures Available Upon Request.

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725 

Visa, MC, AmEx, Discover Cards