GASCO P/N
|
|
|
|
|
|
|
|
COMPANY |
|
| -300 |
|
|
- | - | - | - |
|
|
|
| -301 |
50 PPM
|
50% LEL
|
-
|
-
|
-
|
-
|
AIR
|
BIOSYSTEMS
|
54-9041
|
| -302 |
50 PPM
|
-
|
-
|
50% LEL
|
-
|
-
|
AIR
|
BIOSYSTEMS
|
54-9042
|
| -303E |
50 PPM
|
1.62% = (50%
LEL) Propane simulant
|
18%
|
NITROGEN
|
BIOSYSTEMS
|
54-9042E
|
|||
| -303 |
-
|
50% LEL
|
-
|
-
|
-
|
17%
|
NITROGEN
|
DRAEGER
|
4557019
|
| -304 |
100 PPM
|
50% LEL
|
-
|
-
|
-
|
-
|
AIR
|
DRAEGER
|
4594946
|
| -305 |
100 PPM
|
-
|
30% LEL
|
-
|
-
|
-
|
AIR
|
DRAEGER
|
4594947
|
| -306 |
-
|
20% LEL
|
-
|
-
|
-
|
19%
|
NITROGEN
|
DYNAMATION
|
7800-010
|
| -307 |
200 PPM
|
50% LEL
|
-
|
-
|
-
|
-
|
AIR
|
DYNAMATION
|
7800-016
|
| -308 |
100 PPM
|
20% LEL
|
-
|
-
|
-
|
-
|
AIR
|
DYNAMATION
|
7800-018
|
| -309 |
200 PPM
|
50% LEL
|
-
|
-
|
-
|
19%
|
NITROGEN
|
DYNAMATION
|
-
|
| -310 |
100 PPM
|
50% LEL
|
-
|
-
|
-
|
19%
|
NITROGEN
|
ISC
|
1810-1246
|
| -311 |
100 PPM
|
-
|
25% LEL
|
-
|
-
|
19%
|
NITROGEN
|
ISC
|
1810-1576
|
| -312 |
-
|
-
|
25% LEL
|
-
|
-
|
19%
|
NITROGEN
|
ISC
|
1810-1238
|
| -313 |
100 PPM
|
20% LEL
|
-
|
-
|
-
|
-
|
AIR
|
LUMIDOR
|
GFV123
|
| -314 |
-
|
1.45% = (58%
LEL) Pentane simulant
|
-
|
15%
|
NITROGEN
|
MSA
|
478192
|
||
| -314A |
60 PPM
|
1.45% = (58%
LEL) Pentane simulant
|
-
|
15%
|
NITROGEN
|
MSA
|
478191
|
||
| -315 |
50 PPM
|
50% LEL
|
-
|
-
|
-
|
17%
|
NITROGEN
|
QUEST
|
54-145
|
| -316 |
-
|
1.62%
vol
|
-
|
-
|
-
|
18.0%
|
NITROGEN
|
-
|
-
|
| -317 |
50 PPM
|
-
|
-
|
25% LEL
|
-
|
19%
|
NITROGEN
|
QUEST
|
54-145
|
| -318 |
50 PPM
|
50% LEL
|
-
|
-
|
-
|
12.0%
|
NITROGEN
|
GASTECH
|
81-0155
|
| -319 |
50 PPM
|
50% LEL
|
-
|
-
|
-
|
19.0%
|
NITROGEN
|
-
|
-
|
| -320 |
35 PPM
|
-
|
-
|
-
|
1000
ppm
|
-
|
AIR
|
-
|
-
|
| -321 |
100 PPM
|
50% LEL
|
17.0%
|
NITROGEN
|
-
|
-
|
|||
| -322 |
50 PPM
|
-
|
50% LEL
|
-
|
-
|
-
|
AIR
|
500 PSIG MAX
|
-
|
| -322-18 |
50
PPM
|
-
|
50%
LEL
|
-
|
-
|
18.0%
|
-
|
-
|
-
|
| -323E |
50 PPM
|
1.25%= (50% LEL)
Pentane simulant
|
18.0%
|
NITROGEN
|
BIOSYSTEMS
|
54-9070E
|
|||
| -325 |
35 PPM
|
-
|
10% LEL
|
-
|
-
|
18.0%
|
NITROGEN
|
IST
|
585-110-036
|
| -326 |
40
PPM
|
50%
LEL
|
-
|
-
|
-
|
18.0%
|
NITROGEN
|
-
|
-
|
| -327 |
1000
PPM
|
-
|
-
|
-
|
-
|
2.0%
|
NITROGEN
|
-
|
-
|
| -328 |
100
PPM
|
50%
LEL
|
-
|
-
|
-
|
15.0%
|
NITROGEN
|
-
|
-
|
| -329 |
50
PPM
|
10%
LEL
|
18.0%
|
NITROGEN
|
-
|
-
|
|||
| -330 |
60
PPM
|
50%
LEL
|
-
|
-
|
-
|
15.0%
|
NITROGEN
|
-
|
-
|
| -331 |
50
PPM
|
-
|
-
|
15%
LEL HEXANE
|
-
|
12/0%
|
NITROGEN
|
-
|
-
|
| -332 |
50 PPM
|
-
|
-
|
10% LEL HEXANE
|
-
|
12.0%
|
NITROGEN
|
500 PSIG MAX
|
-
|
| -333 |
-
|
-
|
-
|
30% LEL HEXANE
|
-
|
15.0%
|
NITROGEN
|
-
|
-
|
| -334 |
-
|
-
|
-
|
10% LEL HEXANE
|
-
|
18.0%
|
NITROGEN
|
-
|
-
|
| -335 |
-
|
-
|
-
|
15% LEL HEXANE
|
-
|
12.0%
|
NITROGEN
|
-
|
-
|
| -336 |
-
|
-
|
-
|
50% LEL HEXANE
|
-
|
12.0%
|
NITROGEN
|
-
|
-
|
| -337 |
200
PPM
|
1%
Vol.
|
-
|
-
|
-
|
-
|
NITROGEN
|
-
|
-
|
| -338 |
500
PPM
|
50% LEL
|
-
|
-
|
-
|
-
|
AIR
|
-
|
-
|
| -339 |
900
PPM
|
-
|
-
|
-
|
-
|
9.0%
|
NITROGEN
|
-
|
-
|
| -340 |
-
|
-
|
-
|
-
|
5.0%
|
5.0%
|
NITROGEN
|
-
|
-
|
| -341 |
-
|
-
|
-
|
-
|
5.0%
|
15.0%
|
NITROGEN
|
-
|
-
|
| -342 |
-
|
-
|
-
|
-
|
5.0%
|
1.0%
|
NITROGEN
|
-
|
-
|
|
-343
|
-
|
-
|
-
|
-
|
5.0%
|
7.0%
|
NITROGEN
|
-
|
-
|
|
-344
|
-
|
30%
LEL
|
-
|
-
|
-
|
18.5%
|
NITROGEN
|
-
|
-
|
|
-345
|
-
|
-
|
8%
Butane Simulant
|
13.8%
|
-
|
NITROGEN
|
-
|
-
|
|
Part Number List Continues Below the Pricing
|
|
|
|
The
part # is determined by the cylinder size followed by the appropriate
suffix.
(See example at the bottom of the page) |
||
| Bump-IT 6" Mini Bump Gas Cylinder | BumpIT- |
4-Pack $160.00
12-Pack $450.00 |
| 10 Liter | 10L- |
$45.00
|
| 17 Liter | 17L- |
$32.00
|
| 34 Liter | 34LS- Standard: Steel cylinder for use only with non-reactive gases. Uses the 71-Series regulator. |
$65.00
|
| 34L- Optional: Aluminum cylinder for use with any reactive or non-reactive gases. Uses the 70-Series regulator also used with the 58 liter cylinders. |
$100.00
|
|
| 103 Liter (Steel Cylinder) | 103L- |
$120.00
|
| 44 Liter Cylinders | Standard
Cylinders 44L- |
$115.00
|
| ecosmart
Refillable Cylinders 44ES- 44R- |
$115.00 Refill Only $60.00 |
|
| 66 Liter Cylinders | Standard
Cylinders 66L- |
$140.00
|
| ecosmart
Refillable
Cylinders 66ES- 66R- |
$140.00 Refill Only $70.00 |
|
| 116 Liter Cylinders | Standard
Cylinders 116L- |
$170.00
|
| ecosmart
Refillable
Cylinders 116ES- 116R- |
$170.00 Refill Only $120.00 |
|
| 221 Liter (Steel Cylinder) | 221L- |
$115.00
|
Many
More Mixtures available upon request. |
||
552 Liter Cylinders Nitrogen & Oxygen Mixtures $333.00 All Non-Reactive Single & 2-gas Mixtures $333.00 All Non-Reactive 3-Gas Mixtures $333.00 Cylinder Specifications & Photos
Regulator Specifications & Photos
Download pdf Purchase Order Form
Download Word Purchase Order Form
Instrument Calibration Gas Mixtures - Nonreactive Multiple Gas Mixtures for
Biosystems, ISC, MSA, Draeger, Dynamation, Gasctech, Lumidor, Bacharach, QuestGASCO P/N SUFFIX CARBON MONOXIDE METHANE PENTANE PROPANE CARBON DIOXIDE OXYGEN BALANCE GAS DETECTION
COMPANYTHEIR P/N -346 - 50% LEL 45% LEL - - 15.0% NITROGEN - --347 200 PPM 50% LEL - - - 15.0% NITROGEN - --348 100 PPM 50% LEL - - - 12.0% NITROGEN - --349 200 PPM - 50% LEL - - - AIR - --350 700 PPM 4.0% Vol. - - - - NITROGEN - --351 - 2.5% LEL - - 130 PPM - NITROGEN - --352 - - - - 1900 PPM 5% NITROGEN - --353 - - - - 5000 PPM 5% NITROGEN - --355 300 PPM 1.45% LEL Pentane Simulant - 15% NITROGEN - --356 60 PPM - 25% LEL - - 19% NITROGEN - --357 - - 35% Vol - - 19% NITROGEN - --359 500 PPM 50% LEL - - - - AIR - --360 50 PPM 30% LEL - - - 18% NITROGEN - --360-B 50 PPM 32% LEL - - - 19% NITROGEN - --361 35 PPM 50% Vol - - - - NITROGEN - --362 95 PPM 1.5% Vol - - - - AIR - --363 100 PPM - 25% LEL - 2.5% 19% NITROGEN - --364 250 PPM - 25% LEL - - 19% NITROGEN - - -365 - 2.5% Vol - - 35% NITROGEN - --366 - 50% LEL - - - 19% NITROGEN - --367 100 PPM 25% LEL - - - 19.0% NITROGEN - --368 - 15% Vol - - 15% NITROGEN - --369 100 PPM 50% LEL - - - 19.5% NITROGEN - --370 100 PPM 25% LEL - AIR - --371 35 PPM 1.25%= (50% LEL Pentane simulant) - - AIR - --373 - - - - 500 PPM 5.0% NITROGEN - --374 50 PPM - - - - 18% NITROGEN - --375 100 PPM - - - 1000 PPM - NITROGEN - --376 100 PPM - - - - 3.0% NITROGEN - --377 250 PPM 1.45% Vol - - - 17% NITROGEN - --378 200 PPM - - - - 6.0% NITROGEN - --379 50 PPM - - 50% LEL - 18% NITROGEN - --379S 100 PPM 50% LEL 18% NITROGEN - --380 25 PPM - - - 1000 PPM - AIR - --381 100 PPM 25% LEL - - - 18% NITROGEN - --382 - - - - - 12.0% NITROGEN - --383 1900 PPM - - - - 2.0% NITROGEN - --383B 1000 PPM - - - - 2.0% NITROGEN - --383S 900 PPM - - - - 1.0% NITROGEN - --384 - 25% LEL - - - 19.0% NITROGEN - --385 - 30% LEL - - - 18.5% NITROGEN - --386 35 PPM 10% LEL - - - 19% NITROGEN - --389 50 PPM . - - - 1000 PPM - AIR - --389-35 35 PPM - - - 1000 PPM - AIR - --389N 50 PPM - - - 1000 PPM - NITROGEN - --390 35 PPM 10% LEL - - - 18% NITROGEN - --391 - - - - 5% 1.0% NITROGEN - --392 250 PPM 50% LEL - - - 18% NITROGEN - --393 - 50% LEL 18% NITROGEN - --394 - - - - - - - - --395 50 PPM 50% LEL 2.5% 12.0% NITROGEN - --396 - - - - - - - - --397 - - - - - - - - --398 35 PPM 30% LEL - - - 18.5% NITROGEN - --399 - 50% Vol - - 35% Vol - NITROGEN 500 PSIG Max --399-15 - Balance - - 15% Vol - - - --399-35 - Balance - - 35% Vol - - - --399-M - 60% Vol - - 40% Vol - - - --399-S - 15% Vol - - 15% Vol - NITROGEN - -
Pricing Effective January 2012. Subject to Change Without Notice.
Note: Many More Mixtures Available Upon Request.
Download pdf Purchase Order Form
Download Word Purchase Order Form
Return to Brandt Instruments
For more information Email![]()
Brandt Instruments, Inc.
18568 Oak Grove Parkway
Prairieville, LA 70769
1-800-337-6291
Phone: 225-673-6776
Fax: 225-673-6725
![]()
Copyright © 2002-2013 Brandt Instruments, Inc.Notice: This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures. Brandt Instruments, Inc. reserves the right to make any changes to information, features, and specifications of any product without notice. Brandt Instruments, Inc. has made every effort to ensure the accuracy of information displayed on this web site, however, Brandt Instruments, Inc. is not responsible for typographical errors appearing on this web site. Price and availability information is subject to change without notice.